3.4.1 Operating Environment
The following are the values for the normal operating environment of the radio:
Temperature
(1)
−40°C to +55°C
Solar radiation ≤ 1,120 W/m²
Relative humidity 5–100%
Absolute humidity
0.26–40 g/m
3
Maximum temperature change 0.5°C/min
Maximum wind load at 50 m/s (pole
installed single case)
70 N (front)
(1) Depending on product variant, installation scenario, traffic load, and configuration, the
product might in the highest 10 °C temperature range, temporary reduce the output power.
This depends on the durations of the high ambient temperature.
3.4.2 Heat Dissipation
The radio is designed for outdoor installation.
Avoid indoor installation in a room without adequate ventilation and cooling.
Table 8 Radio Heat Dissipation
Unit Output Power (W) Maximum Heat
Dissipation (W)
Radio 2203 B1
Radio 2203 B2/B25
Radio 2203 B3
Radio 2203 B5
Radio 2203 B8
Radio 2203 B66A
2 x 5 W 90
Radio 2203 B3C
Radio 2203 B7
2 x 5 W 95
Table 9 Support Heat Dissipation
Unit Heat Dissipation (W)
Support 6501
Support 6502
10
Support 6503 20
Radio Description
22
180/1551-LZA 701 6001/1 Uen AC | 2017-11-08