Unit Heat Dissipation (W)
Support 6504
3.4.3 Vibration
The radio operates reliably during seismic activity as specified by test method
IEC 60068-2-57 Ff.
Maximum level of Required Response
Spectrum (RRS)
50 m/s
2
within 2–5 Hz for DR=2%
Frequency range 0.3–50 Hz
Time history signal Verteq II
The radio operates reliably during random vibration as specified by test
method IEC 60068-2-64 Fh method 1
Random vibration,
normal operation
+12 m
2
/s
3
0.3 m
2
/s
3
−12 m
2
/s
3
Frequency range 5–10 Hz 10–50 Hz 50–150 Hz
3.4.4 Materials
All Ericsson products fulfill the legal and market requirements regarding the
following:
•
Material declaration
•
Materials' fire resistance, components, wires, and cables
•
Recycling
•
Restricted and banned material use
3.5 Power Characteristics
This section describes the power supply requirements, power consumption,
and fuse and circuit breaker recommendations for the radio.
The power for the radios can be provided from an AC or a DC power supply.
3.5.1
DC Power Characteristics
The power supply voltage for the radio is −48 V DC.
Technical Data
180/1551-LZA 701 6001/1 Uen AC | 2017-11-08
23