PRELIMINARY
Radio Description
>200
Unit of measurement: mm
Top view Side view
>500
Antenna
Antenna
Radio
Radio
Radio
>200
Radio
>400
>300
Ge8998A
>7 >7
Figure 8 Radio Pole Installation Requirements
To ensure adequate airflow between the units, allow a minimum of 400 mm free
space between radios vertically installed on a horizontal rail on a single pole, or
a dual pole installation. Allow a minimum vertical distance of 500 mm between
radio and antenna, if installed above or below an antenna. The minimum
distance from the bottom of the radio to the floor is 300 mm.
Allow a minimum of 7 mm free space (created by the distance blocks) between
radios installed side by side on the rail.
For Radio 2217 and Radio 2218 allow for a minimum of 40 mm free space
between radios installed side by side on the rail when ambient temperature is
expected to be above +45
î
C.
Note: A radio cannot be installed in the uppermost position of a pole or mast.
3.3.3 Rail Installation on Wall
This section describes the installation requirements when installing the radio
on a wall.
18
181/1551-LZA 701 6001-1-V1 Uen PC3 | 2016-01-13