Installing the AP 6120
Warning!
To comply with FCC radio frequency (RF) exposure limits (FCC OET 65C) for
the general population, antennas must be located at a minimum distance of 7.9
inches (approx. 20 cm) or more from the body of all persons.
2.2 Step 2—Mount on a Flat Surface
The unit should be mounted only to a flat surface that is at least 1/2-inch
plywood or its equivalent. To mount the unit on a ceiling or wall, always use
the pan head Phillips screws provided with the unit.
1. Attach the mounting screws to a ceiling:
• Use the include Screw Hole Template as a guide.
• For concrete or brick walls, drill holes and use the included nylon wall
plugs.
• For T-rail installations, drill 3/32-inch (2.4-mm) pilot holes.
• Leave a 5/16-inch (8-mm) gap so you can slide the unit over the screw
heads.
2. Attach the unit to the mounting screws:
a Line up the two mounting slots on the bottom of the unit with the two
mounting screws.
b Slide the unit across into position so that the mounting screws support
the unit.
c Adjust the screw depth as required so that there is a snug fit between
the unit and the mounting screws.
6
1/006 92-LZA 101 810 Uen A | 2013-04-11