Glossary
option_82 is set to configurable, see section 13.8.23 on page 141. This
parameter is defined using set or unset commands.
option_82_circuit_id <circuit-id> - Content of Circuit ID Sub
option to be used for Option 82. This parameter is used when option_82 is
set to configurable, see section 13.8.23 on page 141.
This parameter is defined using set or unset commands.
static_multicast_groups – This parameter is only defined for the
unset command. It sets the static_multicast_groups IP address to an
undefined value. The add connection command in section 13.8.1 on
page 107 is used to assign an IP address to the static_multicast_groups.
Default Settings
option_82_circuit_id: undefined
option_82_remote_id: undefined
multicast group limit : undefined
Example:
efn# set connection vlan 100 ethernet_port 4 option_82_
remote_id London option_82_circuit_id Site72
13.8.10 set connection_flow
Use this command to define the quality of service parameters on the ingress
flow which do not belongs to a QoS global flow.
reset connection_flow vlan <vlan> ethernet_port <port>
ingress flow <flows> resets the ingress flow values specified to the
defaults.
reset connection_flow vlan <vlan> ethernet_port <port>
egress flows <flows> resets the egress flow values specified to the
defaults.
Syntax
set connection_flow vlan <vlan> ethernet_port <port>
[ingress flow <flows>]
[flow_identifying_values <flow_identifying_values>]
[reliability <reliability>]
[priority <priority>]
Arguments: