Operation
Speed Step Selection
The default speed step selection is 100 as shipped. The 100 speed steps are linear. The 100
speed steps start at a lower threshold, thus the motor is operating at a lower initial voltage
with fine adjustment as the throttle is advanced. The momentum and stall features are not
applicable, and do not operate.
To switch Speed Steps do the following:
Activate 32 Speed Steps: AUX1 + 0 + AUX1 + 0 + BRAKE
Activate 100 Speed Steps: AUX1 + 0 + AUX1 + 0 + BOOST
Note: The speed step selection is stored until changed, and survives power cycling.
Motor Type Selection
The Cruise Commander Lite requires you to set the motor type. Motors are classified as
small or large. Selecting the wrong motor size won’t hurt anything, but operation is best
when matched. The default motor type is “small motor” for the Cruise Commander Lite.
To switch Motor Type do the following:
Activate Small Motor: AUX1 + 0 + AUX1 + 1
Activate Large Motor: AUX1 + 0 + AUX1 + 2
Note: The motor type selection is stored until changed, and survives power cycling.
Cruise On/OFF Selection
The Cruise feature may be turned on or off. This setting is stored and affects command and
conventional mode operation.
To turn the Cruise OFF or ON, do the following:
Cruise Off: AUX1 + 0 + AUX1 + BRAKE + 7 + BRAKE
Cruise On: AUX1 + 0 + AUX1 + BRAKE + 9 + BRAKE
Note: The cruise off/on selection is stored until changed, and survives power cycling.