Do you have a question about the ESAB LAF 1250 and is the answer not in the manual?
Covers user familiarity, responsibilities, workplace safety, PPE, and general precautions.
Explains LAH/LAE to LAF conversion using a kit.
Notes that conversion does not change technical data.
Emphasizes installation must be executed by a professional.
Detailed steps for converting the LAH 630 model.
Steps for converting LAE 800/1000 models.
Steps for converting LAE 1250/1600 models.
Steps to verify the welding power source after conversion.
Details connecting the control box and cables for SAW.
Details connecting cables, gas hose, and water hoses for MIG/MAG.
Caution to read safety information before operating the machine.
Details the adapter for LAF 630 and its ordering number.
Guidance on ordering spare parts, specifying machine type and part number.
| Input Frequency | 50/60 Hz |
|---|---|
| Output Current | 1250 A |
| Rated Output Voltage | 44 V |
| Duty Cycle | 100% at 1250 A |
| Power Factor | 0.93 |
| Protection Class | IP23 |