ESAB LAW 510 Specifications

General IconGeneral
Power SourceInverter
Input Frequency50/60 Hz
Protection ClassIP23
Welding ProcessMIG/MAG
Rated Output500 A / 39 V
Duty Cycle60% @ 500 A
Input Voltage400 V

Summary

Read This First

Safety Warnings

Important safety precautions for arc welding and cutting, including electric shock, fumes, arc rays, fire, and noise hazards.

Component Description LAW 400/500

Connection Diagram, LAW 400/500 400-415 V

Connection Diagram, LAW 400/500 230-500 V

Connection Diagram, LAW; 400-415 V

Connection Diagram, LAW; 230-500 V

Function Description

1 Power Supply, Circuit Board AP1

Details the DC power supplies (+25VC, ±15V, +15VB, +5V, +12V) for the AP1 circuit board.

6 Thermal Overload Cutout

Explains the function of the thermal overload cutout (ST1) and its operating temperatures.

12 Thyristor Circuits

Details the thyristor firing circuits using operational amplifiers IC7 and IC9, and checks for thyristor failure.

13 Processor

Outlines processor functions including frequency measurement, voltage monitoring, overload protection, and hot start.

AP2 Suppression Circuit Board