INSTRUCTION MANUAL (Translation from the original Spanish) EN
Safety instructions for preventing injury and damage to people and property
(See figure 8)
Warning! Observe limitations of use.
This apparatus may be used by children 8 years
or older and persons with reduced physical, sen-
sory or mental capacities, or lacking experience
and knowledge, if they are supervised or receive
adequate training on the safe use of the appa-
ratus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary clean-
ing and maintenance tasks without supervision.
The name plate voltage must be the same as
the mains voltage.
Connect the unit to the mains via an omnipolar
switch with at least a 3 mm
contacts.
Install a high-sensitivity (0.03 A) differential
switch as extra protection against lethal electric
Connect the unit to the ground.
Use unit only within performance limits indicat-
ed on the name plate.
Be careful with hazardous liquids and environ-
ments.
Remember to prime pump.
Caution! Look out for accidental leaks.
Do not expose pump to bad weather.
Check for motor self-ventilation.
Caution! Avoid icing.
Cut out power supply before servicing pump.
Contents
Warning for the safety of people and property ........ 9
1. General points .................................................. 9
2. Handling ......................................................... 10
3. Installation ..................................................... 10
4. Start-up........................................................... 10
5. Operation ........................................................ 11
6. Filterwatch function .......................................... 11
7. Advanced configuration ................................... 12
8. Built-in timer .................................................... 12
9. Maintenance ................................................... 12
10. Declaration of compliance ............................... 13
11. LED indicators ................................................ 13
12. Illustrations ..................................................... 38
Warning for the safety of people and property
The following symbol beside a para-
graph indicates the possibility of danger as a result of
not following the corresponding instructions.
electrocu-
tion risk
Not following this instruction
leads to a risk of electrocu-
tion.
Not following this instruction
leads to a risk of injury to
people or damage to property.
Not following this instruction
leads to a risk of damage to
the pump or the installation.
1. GENERAL POINTS
This manual is complementary to the standard instal-
lation manual for the swimming pool pumps.
The instructions we provide are intended to ensure the
proper installation and optimum performance of
swimming pool water circulation pumps equipped with
SilenPlus
®
frequency inverter and ControlSystem
®
valve position sensor.
Read these instructions before installing.
Keep them for future reference.
Following the installation and usage instructions
and the electrical connection diagrams correctly
ensures that the equipment will work properly.
Ignoring any of the instructions in this manual
can lead to all kinds of consequences for which
we accept no responsibility.
1.1 Product description
SilenPlus pumps equip a standard electric motor with
a built-in frequency inverter. They are designed for a
single phase connection.
They have a radio-frequency transmitter to communi-
cate with the ControlSystem
®
and a Bluetooth
®
connection for remote control using smartphone appli-
cations.
The ControlSystem
®
sensor is the position detector for
a standard swimming pool filter 6-way multiport valve.
It is equipped with electronic sensors for polar posi-
tioning and to control the motor.
The joint working of SilenPlus pumps and the
ControlSystem enables full control of the pump
functions just by operating the filter valve.