EasyManua.ls Logo

Etac Molift Air 200 - User Manual

Etac Molift Air 200
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Molift Air 200 / 350
User manual
BM16199 Rev. I 2022-05-05

Other manuals for Etac Molift Air 200

Question and Answer IconNeed help?

Do you have a question about the Etac Molift Air 200 and is the answer not in the manual?

Summary

About Molift Air

Product Description

Molift AIR is a strong and smooth ceiling lift for comfortable and safe patient transfers.

General Information and Safety

CE Declaration and Compliance

Product complies with regulation (EU) 2017/745 as a medical device, risk class I.

Conditions for Use

Only trained personnel may use the equipment. Rail system must be installed by certified personnel.

Component Compatibility

Recommends using only Molift components. Etac is not responsible for warranty if modifications are made.

Service Personnel Restriction

Only certified personnel can service or repair hoist. Risk of injury from moving parts and electric shock.

Warranty Notice

Warranty Terms

Two-year warranty against defects in workmanship and materials, one-year for batteries.

Product Identification

Product Label Information

The product label barcode contains article number, serial number, and production date.

Warning Labels and Symbols

Symbol Explanations

Detailed explanations of symbols used on the product for user understanding and safety.

Technical Specifications

Safe Working Load and Weight

Specifies maximum load capacity (SWL) and unit weight details.

Battery and Charger Information

Details available battery types and charger specifications.

Dimensions and Hoisting Range

Provides unit dimensions, hoisting ranges for models, and minimum clearance.

Expected Product Lifetime

Indicates the expected operational lifetime of the hoist in cycles and years.

Installation Procedures

Rail and Trolley Installation

Steps for installing the trolley into the rail system, including end stops.

Lifter Mounting to Trolley

Procedure for attaching the lifter to the trolley, noting it requires no tools.

Installation Verification Checklist

Checklist to verify proper installation and safe operation before use.

How to Use Molift Air

General Safety Precautions

Use appropriate accessories, adhere to duty cycle, and follow specific safety warnings.

Pre-use Daily Checks

Daily inspection of lifter, rail, connections, and functions by caregiver.

Hand Control and Operations

Hand Control Features

Details on hand control buttons, indicator light, and safe charging practices.

Electrical Emergency Lowering

Procedure for using the electrical emergency lowering function via the hand control.

Sling Bar Installation

Sling Bar Attachment

Step-by-step guide for correctly aligning and securing the sling bar.

Emergency Functions

Emergency Stop System

How to activate and reset the emergency stop button on the hoist.

Manual Emergency Lowering

Procedure for manual emergency lowering using tools, exclusively for service personnel.

Electronics and Operating Conditions

Transport and Storage Guidelines

Recommendations for storing and transporting the lifter, including temperature range.

Operating Environment

Guidelines for operating the lifter at standard room temperatures and humidity levels, including EMC precautions.

Battery Information

Battery Types and Lifespan

Details on battery types (SLA, LiFePO4), their life expectancy, and charging advice.

Indicator Lights and Service Signals

Charger and Power Supply Indicators

Explanation of indicator lights on chargers and power supplies.

Hoist Battery Indicators

Interpretation of the battery level indicator lights on the hoist.

Service Indicator Signals

Meaning of service indicator lights and periodic inspection requirements.

Charging Systems

Hand Control Charging

How to charge the hand control using a power outlet and compatible chargers.

In Rail Charging (IRC)

Explanation of the In Rail Charging system for continuous charging via the rail.

Transfer Procedures

Planning and Ergonomics

Plan lifting operations for safety and smoothness, considering ergonomics and risks.

Using Slings

Ensure correct sling fitting, strap security, and prior manual review.

Slings from Other Manufacturers

Recommendation to use only Etac or Molift slings due to safety and liability.

Angle Sensor Function

How the angle sensor prevents lifting if the strap angle is too steep.

Lifting and Lowering

Client Interaction

Maintain eye contact and ensure clear space around the client during lifting.

Sling Bar Positioning

The 4-point sling bar must be positioned across the client to prevent sliding.

Accessories

Charger Cords and Plugs

List of available charger cords and plug adapters for different regions.

Sling Bars

Details on available aluminum sling bars (2-point and 4-point) with sizes and part numbers.

Scales

Information on the Molift Scale Set, its compatibility, and features like BMI calculation.

Slings

Overview of Molift RgoSling series, sizes, materials, and combination compatibility.

Transition Coupling

Purpose of Transition Coupling

Used for transferring users between different rail systems, e.g., between rooms.

Disconnecting Transition Coupling

Procedure for safely disconnecting the transition coupling unit.

Connecting Transition Coupling

Procedure for safely connecting the transition coupling units to link rails.

Transfer with Transition Coupling

Disconnected Coupling Check

Verify that both gates are visible and the locking bolt is not visible when disconnected.

Connected Coupling Verification

Ensure coupling is locked securely; rails should not separate by hand.

Cleaning and Disinfection

Cleaning Procedure

Clean regularly with a damp cloth and pH-neutral detergent. Avoid solvents.

Disinfection Guidelines

Use isopropyl alcohol for disinfection. Check emergency stop after cleaning.

Material Exposure

Details materials used and potential for rare allergic reactions in clients.

Safety and Out-of-Service Procedures

Immediate Action for Safety Issues

If lifter poses a safety risk, take it out of service, mark 'out of order', and report.

Periodic Inspection Requirements

Annual inspection by authorized personnel. Report findings and take unit out of service if defects are found.

Troubleshooting

Lifter Not Responding to Hand Control

Check Emergency Stop activation, overheating, or hand control connection/damage.

Lifter Not Responding to Up Button

Verify lifting strap angle sensor activation and adjust strap angle.

Electrical Emergency Lowering Issue

If lifting band is out of wind or wrongly wound, use manual lowering and send for service.

Etac Molift Air 200 Specifications

General IconGeneral
Lifting Capacity200 kg
Safe Working Load200 kg
Power SourceBattery
Emergency StopYes
Emergency LoweringYes
Warranty2 years
MaterialAluminum
Lifting Speed30 mm/s

Related product manuals