USE AND MAINTENANCE MANUAL
ALTERNATIVE DOSING PUMP WITH PISTON
AND SPRING RETURN
Series MP
Type MP 12,5
MP 17,5
MP 25
MP 35
Question and Answer IconNeed help?

Do you have a question about the ETATRON D.S. MP Series and is the answer not in the manual?

Summary

PUMP PRESENTATION

INTENDED USE

Dosing pumps are used to adjust pump capacity for various applications.

PUMPS TECHNICAL DATA

OPERATING CONDITIONS

INTENDED AND NON-INTENDED USE OF THE PUMP

RESIDUAL RISKS

Highlights potential hazards such as leakage from worn gaskets and component degradation.

TRANSPORT, HANDLING, STORAGE

CHECKING ANY DAMAGE OCCURRED DURING SHIPPING

Procedures for inspecting the pump for shipping damage upon arrival.

BLOCK REMOVAL

PUMP INSTALLATION

PUMP POSITIONING

CONNECTING THE PUMP TO THE SYSTEM PIPES

CONNECTION TO THE SUCTION PIPE

Recommendations for short, properly routed suction pipes with appropriate bends and diameter.

CONNECTION TO THE DELIVERY PIPE

INSTALLING THE PULSATION DAMPER

INSTALLATION EXAMPLE

Shows a recommended setup for installing a pulsation damper for better performance.

TOPPING UP LUBRICATING OIL

ACOUSTIC VIBRATION FROM THE PUMP

CONNECTING THE PUMP TO THE POWER SUPPLY

ACTIVATING THE PUMP

OPERATION DESCRIPTION

Covers pre-start checks, oil level, motor rotation, and initial startup for air bleeding.

PUMP REGULATION

STROKE VARIATION WITH MANUAL SYSTEM

Explains how to adjust pump capacity using the manual stroke adjustment knob and nonius.

OPTIONAL EQUIPMENT

STROKE VARIATION WITH SERVO CONTROL

Notes that manual adjustment procedures do not apply when using a servo control.

PUMP CONTROL WITH A PROXIMITY INDUCTIVE SENSOR

ADDITIONAL EQUIPMENT CALIBRATION

OVERFLOW OR OVERPRESSURE VALVE

Provides a scheme and steps for correct installation and adjustment of overflow/overpressure valves.

MAINTENANCE AND REPAIR

SCHEDULED MAINTENANCE

Details visual checks and tasks for ensuring pump security and high performance over time.

FINDING FAULTS

INCONVENIENCES AND CURES

Addresses issues such as liquid leakage, reduced capacity, and air in the delivery pipe with corrective actions.

PTFE GASKET PACK REPLACEMENT AND ADJUSTMENT

GASKET PACK REPLACEMENT (head with execution 21)

Instructions for disconnecting, cleaning, and replacing gasket packs in the pumping head.

PTFE GASKET PACK ADJUSTMENT AND COMPRESSION

Procedure to ensure water-tightness by adjusting and compressing PTFE gasket packs.

HEAD WITH SEAL GASKET CLEANING

SEAL GASKET CLEANING

Method for continuously washing gaskets to remove deposits and prevent hardening.

PUMPING HEAD CLEANING

REPAIRS AT THE FACTORY

DISABLING THE PUMP

DISPOSAL OF HARMFUL SUBSTANCES

ACCESSORIES

ETATRON D.S. MP Series Specifications

General IconGeneral
Frequency50/60 Hz
Voltage230V AC or 110V AC (depending on model)
ControlManual
Material (Pump Head)PVDF, PP
Material (Seals)EPDM