AG-SELECT B1
engineered excellence
Etatron GB Ltd, Newlin Business Park, Exchange Road, Lincoln, LN6 3AB
Question and Answer IconNeed help?

Do you have a question about the Etatron AG-Select B1 and is the answer not in the manual?

Etatron AG-Select B1 Specifications

General IconGeneral
BrandEtatron
ModelAG-Select B1
CategoryController
LanguageEnglish

Summary

Pump Connections

J20 and J21 Connector Information

Provides terminal details for J20 (output 1) and J21 (output 2) connectors.

4-20 mA Output Pump Connection

Instructs to connect the 4-20mA output pump to connector J21.

pH Calibration Procedure

pH Buffer Solutions

Advises having pH 7 and pH 4 buffer solutions and checking their expiry dates.

pH Calibration Steps

Details the process of calibrating the pH sensor using buffer solutions and controller buttons.

mV Calibration Procedure

mV Buffer Solutions

Advises having 650mV or 475mV buffer solutions and checking their expiry dates.

mV Calibration Steps

Details the process of calibrating the mV sensor using buffer solutions and controller buttons.

Factory Reset Procedure