The application of DERMABOND™ PRINEO™ System requires
thorough wound cleansing. Follow standard surgical practice for
wound preparation before application of DERMABOND™ PRINEO™
System (i.e., cleanse, irrigate, debride, obtain hemostasis, and close
deep layers such that there is no tension on the skin edges).
The skin edges must be closely approximated prior to application
of the mesh, so that no signiicant manual approximation is required
during mesh application.
When used in high-tension areas, ensure skin tension has been
removed by application of another wound-closure device
(e.g., sutures or skin staples) prior to application of DERMABOND™
PRINEO™ System, or ensure that the area will be immobilized
during the skin-healing period.
Pat the wound dry with dry, sterile gauze to ensure direct tissue
contact for adherence of the mesh and the liquid topical skin
adhesive to the skin.