KL8-3
8
Press for the first timeThe LIGHTS are ONand the color of LIGHTS are changingPress
againthe current color are changelessPress at the third timesall LIGHTS will OFF
(14) Operation to Constant temperature heating
1) When the pre-heating time is up If the pre-heating has turned on or press the will
also start constant temperature heating system
2After the startup of constant temperature heating circulation pump will be running all the while
3)For exampleif the temperature is set at 35℃, when the water temperature reaches or exceeds
36℃, the heater will be turned off automatically and the circulation pump will stop after 5 secondIf PUMP3
is turn off However when the water temperature reach or lower than 34℃, the heater will start up
4) When the temperature sensor is open/short (LCD shows ”E1”) the auto temperature control
system will not be available Turning on/off the constant temperature system will turn on/off the heater
(15) Operation to blower
there is a key
CF/
controlling the on/off of blower
(16)Fahrenheit & Celsiur temperature shift
In the status ofWaitting Modepressing the key
CF/
can change the mode of Fahrenheit
& Celsiur temperature
(17) When there is no water in the bathtub water pumps blower and constant temperature system will not
start up However the corresponding signal on the LCD will flash
(18) Frozen preventing control
The heater & circulation pump will on when water temperature is under 5℃,And will off when up 10℃。The
function is effective when power on
4.Electric parameters
(1) Performance index
Rated voltage 220VAC/50Hz110VAC/60Hz Maximum working current 60A100A/110V
Voltage-resistance 1250V/1 minute without penetration Isolative resistance >=200MΩ
Water resistance grade IPX5 Electric shock resistance first grade
(2) Output loading index
Heater AC220V/6KW. Surf Water pump AC220V/3 HP
AC110V/3KW AC110V/2HP
Surf+Circulation water pump AC220V/1HP Blower AC220V/1HP
Hot tub under water lamp AC12V/10W Ozone AC12V/15W
Radio 1) Frequency Range FM 87.0~108.0MHz
2) Maximum Output Power 20W
3) Speaker8Ωdamp proof speaker

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ETHINK KL8-3 and is the answer not in the manual?

ETHINK KL8-3 Specifications

General IconGeneral
BrandETHINK
ModelKL8-3
CategoryController
LanguageEnglish