EasyManua.ls Logo

ETHINK KL8800A - Function Instructions; Temperature Control; Operation of the M Key

ETHINK KL8800A
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KL8800A User Manual
www.ethink
-
spa.com
3
9. Single phase, three phase or bi-phase 110V input, 110-120V or 220V-240V output is available.
10. With an additional power supply output, it could connect DVD/TV or any other loads.
11. Switch bank is available to select various functions.
12. Automatic replenishing water and mandatory draining water.
13. Error code hinting.
. Function Instructions
). Temperature Control (77-104 /25 -40 )
Without any setting at the initial, press or key once to enters
temperature setting status. At this time, the setting temperature is flashing on the LCD. Before the
setting temperature stops flashing, each press the or key again to change
the setting temperature value. Without any action in 6 seconds, the system will exit and save
temperature settings and display current actual temperature of the SPA.
In order to ensure the precision of the detected temperature, if no water flowing in the SPA
within 60 minutes, the circulation pump(low speed pump) will automatically turn on and work for
60 seconds.
). The Operation of ” key
1. Press key and hold for more than 5 seconds until it appears a flashing it
represents the system enters to setting mode, and go into a “real-time clock” setting as well.
2. Under the setting mode, click on to set start time of filter cycle”, the LCD is showing
.
3. The 3rd time to click on to set “continuous working period of filter cycle”, the LCD is
showing “ .
4. The 4th time to click on to set “temperature fine tuning , the LCD is showing
.
5. The 5th time to click on to set “LED light brightness adjustment , the LCD is showing
.
6. The 6th time to click on to set mandatory draining water” , the LCD is showing
.