EURGEEN OL12-010-2E - User Manual

EURGEEN OL12-010-2E
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRUCTION MANUAL
Please keep this manual safe for further reference!
Thank you for selecting our super-quality dehumidifier. Please be sure to read this
manual carefully before using it. Any questions, please contact the customer service
for help. Keep this manual for future reference.
The dehumidifier will remove excess moisture from the air, creating a comfortable
environment for your home and office. Its compact design allows it to be easily moved
between rooms.

Questions and Answers

  • A
    Ashley SellersAug 6, 2025
    Why is my EURGEEN OL12-010-2E not working?
    • K
      Kendra SmithAug 6, 2025
      If your EURGEEN Dehumidifier isn't operating, first, ensure it's connected to a functioning outlet and switched on. If the water tank is full, indicated by a flashing light, drain the tank and reset the settings or ensure the tank is correctly placed. The unit has self-protection and cannot operate if the room temperature is below 5°C (displaying "CL") or above 38°C (displaying "CH"). Finally, check if the timer function is active and deactivate it if needed.
  • M
    Megan TuckerAug 13, 2025
    What to do if my EURGEEN OL12-010-2E turns on and off frequently?
    • K
      Kenneth HarperAug 13, 2025
      If the dehumidifying function of your EURGEEN Dehumidifier isn't working properly or the unit frequently turns on and off, start by cleaning the air filter according to the instructions. Make sure that all doors and windows are closed. Ensure the unit isn't near any heat sources and move it to a cooler location if necessary. Also, check for any obstructions in the intake or discharge ducts and remove them.
  • S
    Steven PittsAug 20, 2025
    How to fix EURGEEN OL12-010-2E Dehumidifier error E1?
    • M
      markgayAug 20, 2025
      If your EURGEEN Dehumidifier displays error code E1, it indicates an evaporator sensor problem. Try disconnecting and reconnecting the sensor. If the issue persists, the sensor may need to be replaced.
  • J
    James MillerAug 28, 2025
    How to fix EURGEEN OL12-010-2E error E2?
    • C
      Charles CookAug 28, 2025
      If your EURGEEN Dehumidifier displays error code E2, it means there's an issue with the humidity sensor. Try disconnecting and reconnecting the sensor. If that doesn't resolve the problem, consider replacing the sensor.

Summary

CAUTIONS

General Operating Safety

Read instructions, ensure proper installation, voltage, and avoid water immersion or damage.

Usage Restrictions and Environment

For indoor use only. Keep away from heat sources. Not for unsupervised children.

Maintenance and Repair Safety

Unplug before cleaning. Damaged cords need professional replacement. Do not attempt self-repair.

OPERATIONS

Control Panel Overview

Diagram illustrating the dehumidifier's control panel and its various buttons and indicators.

POWER and Mode Controls

Controls unit on/off, CONT mode, fan speed, and delay shutdown.

Humidity and Timer Settings

Adjusts humidity levels and sets a 24-hour timer for the unit.

Fan Speed and Ionizer Functions

Allows adjustment of fan speed and activation of the ionizer for air purification.

Display Indicators and Water Full Alert

Explains display indicators, humidity readings, color meanings, and water tank full alerts.

WATER DRAINAGE

Water Tank Drainage Procedure

Instructions on removing and emptying the water tank when the full indicator is active.

Continuous Drainage Setup

How to connect a pipe for continuous water removal to an external drain or container.

Drainage Cautions and Notices

Important warnings about blocked outlets, pipe bending, cover usage, and tank maintenance.

MAINTENANCE

General Cleaning Instructions

How to clean the unit's housing using a moist cloth and avoiding solvents or excessive water.

Air Filter Maintenance

Procedures for cleaning the washable air filter, including frequency and washing method.

Dehumidifier Storage Guidelines

Guidelines for storing the dehumidifier during extended periods of non-use.

TROUBLE SHOOTING

Common Operational Issues and Solutions

Addresses common problems like unit not operating, frequent on/off, and error codes E1/E2.

Pre-Service Troubleshooting Checklist

A list of common issues and solutions to review before contacting customer service.

EURGEEN OL12-010-2E Specifications

General IconGeneral
CategoryDehumidifier
ModelOL12-010-2E
Power Consumption220W
Water Tank Capacity2L
Operating Temperature Range5-35°C
Operating Humidity Range30-80% RH
Noise Level45 dB
Power Supply220-240V, 50Hz
Dehumidification Capacity12L/Day (at 30°C, 80%RH)