28
INSTRUCTIONS FOR THE INSTALLER
18






18B
GAS CONNECTION
This appliance shall be installed only by authorised
personnel and in accordance with the manufacturer’s
LQVWDOODWLRQLQVWUXFWLRQVORFDOJDV¿WWLQJUHJXODWLRQV
municipal building codes, water supply regulations,
HOHFWULFDOZLULQJUHJXODWLRQV$6*DV,QVWDOODWLRQV
and any other statutory regulations.
7KHDSSOLDQFHLVDGMXVWHGWRZRUNDWJDVLQGLFDWHGRQ
the label which is applied on the glass-window of the
RYHQGRRUDQGRQWKHFRRNHUSDFNLQJ
Installation for Natural gas
&RQQHFWHGUHJXODWRU%WR¿WWLQJ$ZKLFKLVWKHQ¿WWHG
to elbow (F). Ensure arrow on regulator point in the
direction shown. Fitting (D) to be supplied by installer
¿J$GMXVWUHJXODWRUWRJLYHWHVWSRLQWSUHVVXUH
given on data label on <TECHNICAL FEATURES>
paragraph, with one large or one medium burner
alight at maximum.
3RVLWLRQRI5HJXODWRUÀJ
The stove must be installed on legs, a gas pipe
EHWZHHQ¿WWLQJ$DQG%ZLOODOORZORFDWLRQRIWKH
regulator (B) underneath the stove for adjustment and
maintenance.
Installation for Propane Gas ÀJ$
Connect by using a copper pipe starting, from the threaded
¿WWLQJRIHOERZ)
,QVWDOODWLRQXVLQJÁH[LEOHFRQQHFWLRQ
$VDQRSWLRQWKHFRRNHUPD\EHLQVWDOOHGZLWKD
ÀH[LEOHFRQQHFWLRQKRVHZKLFKFRPSOLHVZLWK$6
1=6$*$$SSURYHGPP,'FODVV%RU
'0LQLPXPPP0D[LPXPPPDVDQ
alternative connection.
$OOFRRNHUVRIIHUOHIWRUULJKWKDQGFRQQHFWLRQ7KH
PDQLIROGKDVDÀDWÀDLURYHUZKLFKLVLQVHUWHGD
screw nut male ½”JDV¿J%
An isolating tap and pressure regulator must be
¿[HGWRWKHUHDUZDOODQGWKHÀH[LEOHSLSHDWWDFKHG
by means of a union connector.
The gas connection and isolating tap must be
accessible to a service person or inspector.
The hose assembly must be installed in accordance
ZLWK$6IRUDKLJKOHYHOFRQQHFWLRQ7KHKRVH
VKRXOGQRWEHVXEMHFWHGWRDEUDVLRQNLQNLQJRU
1RWH:KHQWKHUHJXODWRULVÀWWHGDWWKHUHDURI
the cooker at least 60 mm clearance is required.
permanent deformation and should be able to be
inspected along its entire length. Unions compatible
ZLWKWKHKRVH¿WWLQJVPXVWEHXVHGDQGFRQQHFWLRQV
WHVWHGIRUJDVOHDNV7KH¿[HGFRQVXPHUSLSLQJ
outlet should be at approximately the same height as
WKHFRRNHUFRQQHFWLRQSRLQWSRLQWLQJGRZQZDUGV
7KHKRVHVKRXOGEHFOHDURIWKHÀRRUZKHQWKH
FRRNHULVLQWKHLQVWDOOHGSRVLWLRQ7KHDQWLWLOWLQJ
chain supplied should be anchored to the lower
KRRN¿[HGWRWKHZDOOVRWKDWWKHFKDLQSUHYHQWV
VWUDLQRQWKHKRVHFRQQHFWLRQVZKHQWKHFRRNHULV
pulled forward.