5
• Service and repair: The air conditioner has no user-serviceable parts contained inside.
Do not attempt to disassemble, modify or conduct repairs on this unit. It has been built
in accordance with relevant safety and performance standards. An electrical specialist
must carry out all repairs. Contact our after sales support centre for advice on service.
• Riskofre: This appliance contains a ammable refrigerant. Do not open the
appliance. In case of damage or malfunction, turn o the appliance, disconnect the
power supply and call our after sales support centre for a service.
Installation
• Proper installation: Install the appliance according to the instructions in this manual
and national wiring regulations. Improper installation may result in the risk of re,
electric shock and/or injury.
The air extraction opening from the room shall be as low as practicable. The air extraction
openings shall be located in a sucient distance from the air intake openings to prevent
re-circulation to the space.
• WARNING: Electric shock hazard! Before installation or servicing, ensure the unit is
switched o and disconnected from the power outlet to prevent possible injury.
• The location: When deciding on an installation place, keep in mind that the area must
be at, the air outlets must not be covered up, and there must be a properly earthed
220–240 V~ 50 Hz power outlet nearby.
Do NOT install/use the appliance in the following areas:
– Outdoors or where water is likely to splash
– Near a bath, shower, laundry basin or swimming pool
– In an area where oil is likely to splash
– Near a hot gas or electric burner, or sources of re
– Near sources of heat, or exposed to direct sunlight
– In an area where furniture or other objects can obstruct the airow
In the presence of ammable substances or vapour such as alcohol, insecticides,
petrol, etc.
– At a dry cleaner’s premises.
• Clearances: There must be a clearance of at least 30 cm between the appliance and
any walls, furniture, curtains or any other obstacles. Maintaining this minimum 30 cm
clearance is essential; failure to keep that distance can result in the unit malfunctioning
or causing injury.
• Window application: The air exhaust can be installed in a vertical or horizontal sliding
window.
• Air exhaust installation instructions follow on pages 10-12. Keep the length of the air
exhaust hose to the minimum length necessary during operation.
• Upright position: Place the unit on a at surface to reduce the risk of it tipping over. Do
not tilt the unit, always keep it upright during installation and use.
• Misuse: We accept no responsibility for any eventual injuries or damages caused by
improper installation, faulty use or failure to follow the instructions.
PressureSpecications
Permissible excessive operating pressure: discharge 2.5 MPa, suction 1.2 MPa.
Maximum allowable pressure: 4.2 MPa.