WARNING!
Thewaterinletandoutletmustbeinstalledcorrectly,otherwisetheHeatercannot
function.
Donotuseplumbingclementonconnection.Ifnecessary,useonlythreadorsealing
tape.
ElectricalConnection
WARNING!
Theproductmustbeearthed.Impropergroundingcouldcauseelectricalshock.
Makesuretheelectricalmainsisswitchedoffbeforecarryingoutanyelectricalwork.
RefertoWiringLoadingTableforthecorrectcablesize.
Useatleast2.5mm
2
doublecoatedcable.
LeadthepowercablefromtheMCBtoa“ON/OFF”doublepolelinkedswitchhavinga
contactseparationofatleast3mminallpolesoutsidethebathroom,thenleadacable
connectedtoterminalblockinsidetheunit.(seeFig.2)
1. Insertthecable
throughtherubbergrommetforsideentryorwallembeddedentry.
2. Connectthecabletoterminalblockandfullytightenthemasfollow(seeFig.3):
BROWNorRED‐‐‐LIVE(L)
BLUEorBLACK‐‐‐NEUTRAL(N)
GREENorGREEN/YELLOW‐‐‐EARTH(
)
WARNING!
Ensurethewiringconnectioniscorrect.
3. PullouttheTemperatureControlKnobfromtheFrontCover.
4. ReplacetheFrontCover.
5. ReplacetheTemperatureControlKnobandtightenthescrewatthebottomoftheHeater.