FAN: D12BM-12 120mm x 120mm x 25mm (Part No: FAN-C)
We use the above mentioned fan, for the reliability and longevity of a ball bearing fan. The
air flow is good at 72 CFM and is an acceptable noise level for the customer.
REPLACEMENT: (Part No: FAN-C)
To replace the fan if faulty, remove the 9 screws securing the engine bay cover andremove
the cover. The fan will be located on the right hand side of the engine bay. Stand the
cabinet on its end and undo the 10 screws holding the engine bay base to the cabinet.
Carefully drop the base just enough to undo the bottom 2 screws on the fan. Then with a
long screw driver undo the remaining top 2 screws through the holes in the vent . Trace the
wires back to the module, unclip the old fan from the connector at the module and fit new.
Re-attach the new fan, with the metal fan cowl (sticker side facing out).
Note: Evakool normally have the fan cool across the condenser into the engine bay, but
because of restrictions due to size and piping layout, this model draws air from the engine
bay across the condenser.
FILTER DRIER: (Part No. DRIER-FILTER-1)
We strongly advise to only use Evakool filter driers. Copper spun driers are made with
spring loaded sieves to prevent the desiccant from breaking down and blocking capillaries
(the unit is subject to heavy knocks and vibration as a portable appliance).