RampMaster II
Easy Reference Programming
Cone Fire Mode
This method is used to fire ceramics, porcelain, & pottery to a specific cone number
using different firing times. Total firing times may vary depending on cone number selected.
13 hours to reach 04 Cone 7 hours to reach 04 Cone
10 hours to reach 04 Cone 4 hours to reach 04 Cone
Example: Simple 7 hour firing:
1. Turn Power Switch On (Proceed once WAIT is no longer in the display)
2. Press the Button, then the Button.
3. Press the number keys for the Cone you wish to fire, then the Button.
Such as for an 04 Cone
4. Press the number keys for the amount of Hold time desired, then the Button.
Such as . for 15 minutes
5. Press the number keys for the rate of cool down desired, then the Button.
(If none, then enter “0” and it will skip this option and go to IDLE)
Such as for 150 degrees an hour
6. Press the number keys for the temperature you wish to control the cool down to, then
the Button.
Such as
for 1500 degrees
7. Press the number keys for the amount of hold time you wish to hold the end
temperature, then the Button.
Such as
. for no hold time.
8. Press the Button
The display will read “-- -- -- --“.
9. Press the Button to initiate the firing.
For more complex firings using additional features, refer to your complete operating manual.

Other manuals for Evenheat RampMaster II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Evenheat RampMaster II and is the answer not in the manual?

Evenheat RampMaster II Specifications

General IconGeneral
Number of Programs8
Number of Segments per Program8
Output TypeRelay
MemoryNon-volatile
Input Voltage120V or 240V
Controller TypeRamp/Soak
Control Accuracy±1°F
Input TypeThermocouple Type K
DisplayDigital
ProgrammabilityFully programmable