4
Pre-Installation (continued)
PRODUCT DESCRIPTION
A
B
C
D
Part Description
A Discharge pipe with weep hole
B Coupling pipe
C Pipe with check valve
D Additional discharge pipe
FOR EXISTING INSTALLATIONS – BEFORE YOU BEGIN INSTALLATION
If you are installing this Sump Pump Discharge Kit into an existing installation, complete these steps before you install the Sump Pump
Discharge Kit.
1. Unplug your pump.
2. If your system is sealed, disconnect the vent from your cover.
3. Disconnect the existing discharge pipe at the inlet to your old check valve.
4. Remove the cover from your basin.
5. Remove the pump and the attached discharge pipe from your basin.
6. Drain the discharge pipe above the check valve into the basin or a bucket by pushing the apper in the check valve up with your nger
or a blunt object. Be careful. It may get messy.
7. Remove your old check valve from the existing discharge pipe.