Rev. 03/08/04
775-9203A
1
ALWAYS READ
INSTRUCTIONS
BEFORE USING
POWER TOOLS
ALWAYS WEAR
SAFETY GOGGLES
WEAR HEARING
PROTECTION
AVOID
PROLONGED
EXPOSURE TO
VIBRATION
INSTRUCTION MANUAL & PARTS BREAKDOWN
775-9203A
6" DAQ SANDER
Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to cause cancer, birth defects
or other reproductive harm. Some examples of these chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement
and other masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those
dust masks that are specially designed to filter out microscopic particles.
Specifications
Free Speed . . . . . . . . .10,000 RPM
Air Inlet (NPT) . . . . . . . . . . . .1/4"
Hose Size (ID) . . . . . . . . . . . . .3/8"
Air Pressure (PSI) . . . . . . . . . . . .90
Air Consumption . . . . . . . . . . . .4
Pad Size . . . . . . . . . . . . . . . . . .6"
Sound Level . . . . . . . . . . . .91 dBA
Height . . . . . . . . . . . . . . . . . . . .5"
Length . . . . . . . . . . . . . . . . .9-3/4"
Shipping Wt. (Lbs.) . . . . . . . . .4.22

Questions and Answers

  • M
    Mary FranklinAug 1, 2025
    Why does my Evercraft 775-9203A tool run slowly or not at all?
    • S
      Shannon AllenAug 1, 2025
      Your Evercraft Sander might be running slowly or not at all due to a few reasons: airflow could be blocked by dirt, motor parts might be jammed with dirt, or the power regulator could have vibrated to a closed position. To resolve this, first check the air inlet strainer for any blockage. Then, pour a generous amount of air tool oil into the air inlet and operate the tool in short bursts, both forward and reverse. Repeat if necessary. If the issue persists, it's recommended to have it serviced at an authorized service center.
  • C
    Christian MartinezAug 10, 2025
    What to do if my Evercraft 775-9203A tool will not run, but exhaust air flows freely?
    • D
      Daniel MurphyAug 11, 2025
      If your Evercraft Sander tool won't run, but exhaust air flows freely, it could be that one or more motor vanes are stuck due to sludge or varnish, or the motor is rusted. To attempt a fix, pour a generous amount of air tool oil into the air inlet and operate the tool in short bursts, both forward and reverse. Lightly tap the motor housing with a plastic mallet. Detach the air supply and try to free the motor by turning the drive shank manually, if possible. If the tool remains jammed, it should be serviced at an authorized service center.
  • G
    Gary WilliamsAug 20, 2025
    What to do if my Evercraft Sander tool will not shut off?
    • T
      Tonya JonesAug 20, 2025
      If your Evercraft Sander tool will not shut off, it could be due to a broken or mispositioned throttle valve O-ring, or a bent or jammed throttle valve stem. Remove the assembly and install a new O-ring. Lubricate it with air tool oil and operate the trigger briskly. If the operation cannot be restored, the tool should be serviced at an authorized service center.

Summary

Specifications

Health and Environmental Precautions

Warnings about dust exposure, cancer, birth defects, and reproductive harm from sanding.

General Safety Warnings

Safe Operation Guidelines

Essential safety practices for operating and maintaining the power tool.

Tool Operation and Maintenance

Lubrication and Air Supply

Procedures for daily lubrication and requirements for air supply quality and pressure.

Operating Instructions

Guidance on throttle control, sander operation, and proper work technique.

Parts Breakdown

Component List and Diagram

Detailed identification of all parts for the 6" DAQ Sander with a visual diagram.

Troubleshooting - Impact Wrenches and Air Ratchets

Problem Diagnosis and Solutions

Solutions for common issues encountered with impact wrenches and air ratchets.

Troubleshooting - Air Drills and Air Hammers

Problem Diagnosis and Solutions

Solutions for common issues encountered with air drills and air hammers.

Evercraft 775-9203A Specifications

General IconGeneral
BrandEvercraft
Model775-9203A
CategorySander
LanguageEnglish