SYMPTOM POSSIBLE CAUSE
Spark failure
(1) Faulty igniter
(2) Incorrect spark gap
(3) Loose or faulty connections
Failure to ignite even
with spark present
(1) No gas
(2) Incorrect injectors
(3) Incorrect gas type
(4) Air in gas lines
(5) Faulty thermocouple
(6) Faulty tilt switch
Dull or uneven burners
(1) Partially blocked injectors
(2) Burner venturi blocked
(3) Dirty burner tiles
Burner flashing back
(l) Cracked burner tile
(2) Faulty or incorrect injector
(3) Injector loose
(1) Pilot ports partially blockedVery high pilot flame
REMEDY
Replace
Reset to 4.5mm
Check with meter
Check supply
Replace injectors
Check gas for which unit
was intended
Purge all lines
Replace ODS
Replace
Clean or replace injectors
Check and clean (possibly
insect such as wasp)
Clean with compressed air
Replace
Replace injector
Tighten
Clean with compressed air or
a vacuum cleaner
Please Note:
Darkening of the heater tile face is a natural consequence of the gas combustion process.
Servicing shall be carried out only by authorised personnel.
If unit fails to ignite after following these instructions, contact your nearest authorised EVERDURE
service agent or: