15
ENGLISH
NB: If the required temperature is not reached within the scheduled time (positive chilling: 90 min,
freezing: 240 min), the control board emits a repeated loud bleep as a warning.
The blast chiller keeps chilling / freezing until reaching the scheduled temperature. Failure of reaching
the temperature within the scheduled time may take place when introducing products which are
bigger in size or weight compared with the standard ones or products with higher temperature of the
maximum allowed.
9.2.6 SOFT TIME-BASED CHILLING and subsequent storage
In order to select a time-based chilling cycle, you just need to make sure not to insert the core probe.
The Soft time-based and storage cycle consists in two phases:
1st phase:Soft chilling cycle (Room temp. setpoint 0°C during the whole cycle)
2nd phase: Storage phase (Room temp. setpoint 2°C)
- Make sure the core probe is not inserted.
- Make sure the blast chiller is in “ON/STAND-BY” mode, that the keyboard is not locked (chapter
11) and that no procedures are being carried out.
Press and release the key the icon starts ashing
The display shows the working setpoint during chilling.
It is possible to use the keys to modify this value and modify the values with the same keys
Press and release the key within 20
seconds:
The
icons remain on and the cycle
starts
The control board carries out a one-minute test, to make sure the core probe has been cor-
rectly inserted, the icon ashes during the whole test, and turns off at the end of it.
If the core probe has not been correctly inserted, the acoustic buzzer warns us 3 times (each
10 seconds).
There is no need to press any keys, a time-based cycle will automatically begin.
During the chilling, the display shows the temperature detected by the room probe and the
and min icons remain on.
It is possible to modify the duration of the cycle by pressing the keys.
To display the room’s temperature, press and release the . To restore the standard
display mode, press and release the same key or do not operate for 15 seconds.
Once the chilling has been completed, according to the scheduled duration, the blast chiller
automatically switches to storage.
-During storage, the display shows the temperature detected by the probe, and the icon is on
.
To stop the cycle, press the key.