Do you have a question about the Eversolar Eversol-TL5400 and is the answer not in the manual?
Defines the manual's applicability and identifies the intended audience for installation.
Covers requirements for keeping documents and product CE certification details.
Outlines technical compliance requirements and safety regulations for installation and operation.
Lists all components included in the inverter package for verification.
Procedure for inspecting the inverter and packaging for any damage incurred during shipping.
Specifications related to the DC input from the PV generator, including voltage and current.
Specifications related to the AC output to the grid, including power and voltage ratings.
Details on the inverter's efficiency ratings and integrated safety equipment.
General specifications such as operating temperature, IP rating, cooling, and display types.
Guidance on choosing an installation location, considering dimensions, weight, and ambient conditions.
Step-by-step procedure for physically mounting and installing the inverter unit.
Instructions for safely connecting the inverter to the PV generator (DC) and the public grid (AC).
Procedure for starting the inverter and information on monitoring via RS232/RS485.
Details on the inverter's built-in safety features, including GFCI, isolation, and anti-islanding.
| Max. Input Voltage | 550 V |
|---|---|
| Number of MPPT Trackers | 2 |
| Nominal AC Voltage | 230 V |
| AC Output Voltage | 230 V |
| Max. Output Current | 23.5 A |
| European Efficiency | 96.5 % |
| Protection Degree | IP65 |
| Max. AC Power | 5400 VA |
| Maximum AC Output Power | 5400 VA |
| AC Output Frequency | 50/60 Hz |
| Operating Temperature Range | -25°C to +60°C |