1
AN158 ON/OFF MODULE
This plug-in ON/OFF Module is a transceiver which is a Z-Wave
TM
enabled device
and is fully compatible with any Z-Wave
TM
enabled network. Z-Wave
TM
enabled
devices displaying the Z-Wave
TM
logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
enabled
networks. Remote On/Off control of the connected load is possible with other
manufacturer’s Wireless Controller. Each module is designed to act as a repeater.
Repeaters will re-transmit the RF signal to ensure that the signal is received by its
intended destination by routing the signal around obstacles and radio dead spots.
The plug-in ON/OFF Module is compatible with our Motion Detectors SP814 and
Door/Window Detectors SM103.
This plug-in ON/OFF Module is able to detect current wattage (5~3150W) and
overload wattage (3010~3300W) of connected non-dimmable lights or appliances.
When detecting overload state, the Module will be disabled and its On/Off button will
be locked out of which LED will flash quickly for 30 seconds. However, unplug and
re-connect the Module will reset its overload condition to normal status.
Include to or Exclude from a Z-Wave
TM
Network
In the front casing, there is an On/Off button with LED indicator which is used to carry
out inclusion, exclusion, reset or association. Toggle On/Off button between On and
Off. When first power is applied, its LED flashes on and off alternately and repeatedly
at 2-second intervals. It implies that it has not been assigned a node ID and cannot
work with Z-Wave enabled devices. Please get familiar with the terms below before
starting the operations.
Function Description
Inclusion Add a Z-Wave enabled device (e.g. On/Off Module) to Z-Wave network.
Exclusion Delete a Z-Wave enabled device (e.g. On/Off Module) from the network.
Function Description
Association After inclusion, you have to define the relationship between devices.
Through association, device can be assigned as master/slave, and specify
which slave is going to be controlled by which master.
Reset Restore On/Off Module to factory default.
The table below lists an operation summary of basic Z-Wave functions. Please refer
to the instructions for your Z-Wave
TM
Certificated Primary Controller to access the
setup function, and to include/exclude/associate devices.
Function Description LED Indication
No node ID The Z-Wave Controller does not allocate
a node ID to the Module.
2-second on, 2-second off
1. Have Z-Wave Controller entered
inclusion mode.
Inclusion
2. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
Press On, for on
Press Off, for off
1. Have Z-Wave Controller entered
exclusion mode.
2. Pressing On/Off button three times
within 1.5 seconds will enter
exclusion mode.
Press On, for on
Press Off, for off
Exclusion
Node ID has been excluded. 2-second on, 2-second off
1. Pressing On/Off button three times
within 1.5 seconds will enter
inclusion mode.
2. Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
Press On, for on
Press Off, for off
Reset
3. IDs are excluded. 2-second on, 2-second off
1. Have Z-Wave Controller entered
association mode.
Or Pressing On/Off button three times
within 1.5 seconds will enter
association mode
Press On, for on
Press Off, for off
Association
2. There are two groupings - 1 and 2.
Refer to Z-Wave’s Groups as
described on page 3 & 4.
On/Off Button
LED Indicator
Question and Answer IconNeed help?

Do you have a question about the EVERSPRING AN158 and is the answer not in the manual?

Summary

AN158 ON;OFF Module Overview

Z-Wave Network Inclusion and Exclusion

Explains how to add or remove the module from a Z-Wave network using its button and LED indicator.

Module Operation and Setup

LED Status Indicators

Describes the meaning of the LED indicator states for module operation and status.

Choosing Installation Location

Provides guidance on selecting an optimal placement for the module to ensure proper functioning.

Installation Procedure

Details the physical steps required to connect and install the ON/OFF Module into a wall outlet.

Z-Wave Programming Basics

Explains how to program the module using Z-Wave commands for control and automation.

Z-Wave Association Groups Management

Group 1: Status Reporting

Covers Grouping 1, including POWER_APPLIED, SWITCH_BINARY_REPORT, and METER_REPORT commands for status updates.

Group 2: Device Control

Explains Grouping 2, focusing on BASIC_SET commands for controlling other Z-Wave devices.

Advanced Z-Wave Configuration

Configuration Parameters Explained

Defines Z-Wave configuration parameters for true period, basic commands, and meter report intervals.

Meter Command Class Functionality

Explains the Meter Command Class for reporting instant and accumulated power consumption in Watts and KWh.

Troubleshooting and Specifications

Troubleshooting Common Issues

Provides common symptoms, causes of failure, and recommended solutions for module operational issues.

Socket Type Variations

Lists socket types for different European countries, indicating regional compatibility.

Product and Environmental Information

Detailed Product Specifications

Details the technical specifications of the AN158 ON/OFF Module, including voltage, load, range, and frequency.

Environmental Disposal Warning

Advises on proper disposal of electrical appliances and environmental concerns.

EVERSPRING AN158 Specifications

General IconGeneral
BrandEVERSPRING
ModelAN158
CategoryControl Unit
LanguageEnglish

Related product manuals