REPLACE METER
CLEAN INJECTOR ASSEMBLY
1.
Disconnect the meter cable from the
meter. (If  ow meter cable is attached)
2. Disconnect the bypass from valve by removing clips.
3. Remove the coupling adapter from
the bypass.
4. Remove the meter support from the
bypass.
5. Remove the meter and replace it.
C o u p l i n g
Adapter
Meter
Support
Meter
Injector Cap
O-ring on Cap
2×Screws
Screen
Injectors
1. Remove the two screws of the injector cap.
2. Pull the injector cap out, watch for the o-ring on the cap.
3. Screw the injector assembly out, clean/replace it.
4. Pull the screen out, clean/replace it.
5. After servcing, reverse following steps in this section.
Meter Ball
2 X Screws
2 X Clips