REPLACE DRAIN LINE FLOW CONTROL
REPLACE BRINE LINE FLOW CONTROL
REPLACE MOTOR
1. Follow steps 1 to 3 of Timer /Powerhead replacement.
2. Remove the two screws from the motor. Remove motor( disconnect the wire attached on PCB if any), watch
for the pin under the motor.
3. Replace the motor.
1. Pull the drain line clip and remove the
drain line elbow and washer.
2. Clean/replace drain line  ow control
.
DLFC
1. Screw the copper  tting out.
2. Remove the retainer out.
3. Clean/replace the BLFC button.
2 X Screws
Copper Fitting
BLFC
Retainer
Motor