BOILER ADJUSTMENT
15
Chapter 4
CURRENT DATE AND TIME SETTING
Inside this menu it is possible to set the current day, hours and minutes.
Controls procedure:
Press key 3 (menu/ok) to access the menu.
Press key 3 (menu/ok) to access the “ USER MENU”.
Select “ CLOCK SET MENU” using buttons 4(-) and 5(+) and press key 3 (menu/ok) to con rm.
CLOCK SET 1 MENU D DAY CLOCK
Allows to use buttons 4(-) and 5(+) to set the current day that ashes (Monday - Tuesday).
To con rm and continue programming, press button 3 (menu/ok).
Press button 1 to escape (esc).
CLOCK SET 2 MENU D HOURS CLOCK
Allows to use buttons 4(-) and 5(+) to set the current hours ( ashing).
To con rm and continue programming, press button 3 (menu/ok).
Press button 2 (set) to go back to the previous parameter.
Press button 1 to escape (esc).
CLOCK SET 3 MENU D MINUTES CLOCK
Allows to use buttons 4(-) and 5(+) to set the current hours ( ashing).
To con rm and continue programming, press button 3 (menu/ok).
Press button 2 (set) to go back to the previous parameter.
Press button 1 to escape (esc).
C.HEAT. CONFIGURAT
The Extra ame boilers have the possibility to manage di erent external devices through the circuit board.
One of these devices can be a gas boiler which is de ned as an auxiliary boiler (AUX C.HEAT). It is called
auxiliary as its functioning is managed by the circuit board of the biomass boiler or due to an exact choice
on behalf of the user or due to a block of various nature (fuel exhaustion, an alarm, a manual or automatic
switch-o given by the weekly programmer).
The boiler con guration allows to choose in which way to use the auxiliary boiler.
There are 3 possible settings:
BIOMASS C.HEAT
BIOMASS / AUX
AUX C.HEAT.
BIOMASS C.HEAT: Only the biomass boiler works with this con guration.
BIOMASS/AUX: With this con guration, the biomass boiler always has priority with respect to the auxiliary
boiler. If for any reason (fuel exhaustion, any alarm except for HIGH WATER TEMP etc) the biomass boiler
blocks and cannot restart its normal functioning, the auxiliary boiler is activated. The biomass boiler circuit
board will supply power to the auxiliary boiler and will decide ignition/switch-o of the latter depending on
the requests analysed by the various devices in the plant and connected to the circuit board (e.g. domestic