B-Series – Data Sheet 7
B5K125-24 B5K125-24P2 B5K125-48 B5K125-48P2
Power Requirements
Normal Input Voltage 100 - 240 VAC 100 - 240 VAC 100 - 240 VAC 100 - 240 VAC
Input Frequency 50 – 60 Hz 50 – 60 Hz 50 – 60 Hz 50 – 60 Hz
Input Current 2 A Max 7.5 A Max 2 A Max 7.5 A Max
Power Consumption 59 watts 98 watts 94 watts 125 watts
Temperature
IEC 6-2-1
Standard Operating
Temperature
0° to 50° C
(32° to 122° F)
0° to 50° C
(32° to 122° F)
0° to 50° C
(32° to 122° F)
0° to 50° C
(32° to 122° F)
IEC 6-2-14
Non-Operating
Temperature
-40° to 70° C
(-40° to 158° F)
-40° to 70° C
(-40° to 158° F)
-40° to 70° C
(-40° to 158° F)
-40° to 70° C
(-40° to 158° F)
Heat Dissipation 200 BTUs/Hr 335 BTUs/Hr 321 BTUs/Hr 427 BTUs/Hr
Humidity
Operating Humidity 5% - 95% non-condensing 5% - 95% non-condensing 5% - 95% non-condensing 5% - 95% non-condensing
Vibration
IEC 68-2-6, IEC68-2-36 IEC 68-2-6, IEC68-2-36 IEC 68-2-6, IEC68-2-36 IEC 68-2-6, IEC68-2-36
Shock
IEC 68-2-29 IEC 68-2-29 IEC 68-2-29 IEC 68-2-29
Drop
IEC 68-2-32 IEC 68-2-32 IEC 68-2-32 IEC 68-2-32
Acoustics
Front of switch
(normal operation)
45.5 dB 45 dB 46 dB 45.5 dB
Altitude
Operating 10,000 ft (3,048 m) 10,000 ft (3,048 m) 10,000 ft (3,048 m) 10,000 ft (3,048 m)
Non-operating 15,000 ft (4,572 m) 15,000 ft (4,572 m) 15,000 ft (4,572 m) 15,000 ft (4,572 m)
Agency and Regulatory Standard Specifications
Safety UL 60950-1, CSA 22.1
60950, EN 60950-1, and
IEC 60950-1
UL 60950-1, CSA 22.1 60950,
EN 60950-1, and IEC 60950-1
UL 60950-1, CSA 22.1 60950,
EN 60950-1, and IEC 60950-1
UL 60950-1, CSA 22.1
60950, EN 60950-1, and
IEC 60950-1
EMC FCC Part 15 (Class A),
ICES-003 (Class A), BSMI,
VCCI V-3, AS/NZS CISPR 22
(Class A), EN 55022 (Class
A), EN 55024, EN 61000-3-
2, and EN 61000-3-3
FCC Part 15 (Class A), ICES-
003 (Class A), BSMI, VCCI
V-3, AS/NZS CISPR 22 (Class
A), EN 55022 (Class A), EN
55024, EN 61000-3-2, and EN
61000-3-3
FCC Part 15 (Class A), ICES-
003 (Class A), BSMI, VCCI
V-3, AS/NZS CISPR 22 (Class
A), EN 55022 (Class A), EN
55024, EN 61000-3-2, and EN
61000-3-3
FCC Part 15 (Class A),
ICES-003 (Class A), BSMI,
VCCI V-3, AS/NZS CISPR
22 (Class A), EN 55022
(Class A), EN 55024,
EN 61000-3-2, and EN
61000-3-3
Environmental 2002/95/EC (RoHS
Directive), 2002/96/EC
(WEEE Directive), Ministry
of Information Order #39
(China RoHS)
2002/95/EC (RoHS
Directive), 2002/96/EC
(WEEE Directive), Ministry of
Information Order #39 (China
RoHS)
2002/95/EC (RoHS
Directive), 2002/96/EC
(WEEE Directive), Ministry of
Information Order #39 (China
RoHS)
2002/95/EC (RoHS
Directive), 2002/96/EC
(WEEE Directive), Ministry
of Information Order #39
(China RoHS)
Switch Model Specifications (cont.)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks B-Series B5 and is the answer not in the manual?

Extreme Networks B-Series B5 Specifications

General IconGeneral
BrandExtreme Networks
ModelB-Series B5
CategorySwitch
LanguageEnglish

Related product manuals