Extron DTP T UWP 4K D Series • Remote Control 16
Command and Response Table for SIS Commands
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Auto Switch mode
Disable
E
0AUSW
}
Ausw0
]
Manual input switching
Priority to highest active input
E
1AUSW
}
Ausw1
]
Gives priority to the highest numbered
active input (default)
Priority to lowest active input
E
2AUSW
}
Ausw2
]
Gives priority to the lowest numbered
active input
Auto switch mode status
E
AUSW
} X@
]
Ausw
X@
]
Verbose mode 2/3
Video mute
Enable video and sync mute
2b/B
Vmt2
]
Mutes video and sync
Enable video mute
1b/B
Vmt1
]
Mutes video to black screen with sync
Disable video mute
0b/B
Vmt0
]
Video mute status
b/B
X#
]
Vmt
X#
]
Verbose mode 2/3
Output 5V mode
Set output 5V mode
E
M
X$
HPLG
}
HplgM
X$]
Output 5V mode status
E
MHPLG
} X$]
HplgM
X$]
Verbose mode 2/3
4K video pass-thru mode
Set TMDS pass-thru mode
EX!
*
X&
VPBP
}
Vpbp
X!
*
X&]
View TMDS pass-thru mode status
EX!
VPBP
} X&]
Vpbp
X&]
Verbose mode 2/3
NOTES:
X! = Input number
X@ = Auto switch mode
X# = Video mute
X$ = Output 5V mode
X& = TMDS pass-thru mode
1
through max number of outputs
0 = disabled (default)
1 = enabled (highest active input has priority)
2 = enabled (lowest active input has priority)
0 = Unmute video and sync (default)
1 = Mute video to black screen while sync on
2 = Mute video and sync
0 = Auto (5V enabled when source with 5V present, else off)
1 = 5V always enabled (default)
0 = On
1 = Off
2 = Auto (default)