2
FEATURES AND CONTROLS
• Check the run - tow switch under the seat, make sure it is set in the RUN position.
• Turn off all accessories.
The storage time for properly charged Lithium-Ion batteries supplied with this vehicle varies based on the ambient
temperature.
Setting State of Charge (SOC)
The optional SOC meter or the hand held programmer may be used to determine the state of charge of the battery
module. If the SOC is below 30%, charge the battery module until the state of charge reaches 50%. The charge cycle
may be interrupted by disconnecting the charger from the AC power source first, then from the charging receptacle on
the vehicle. If the SOC is above 50%, operate the vehicle until the SOC is below 50%.
During Storage
Check the state of charge every 30 days. If the SOC is below 30%, charge the battery module until the state of charge
reaches 50%.
Returning Vehicle to Service
At the end of the storage period, charge the battery module to 100% before operating the vehicle.
BATTERY DISPOSAL
Lithium-Ion batteries are recyclable:
• Contact the distributor or manufacturer for information on returning or recycling used or damaged battery
packs.
•Contact local or state environmental department for disposal information.
•Refer to the Maintenance section for additional information.
Temperature Length of Storage Time
-22°F to -4°F (-30°C to -20°C) One month at 100% battery charge, all accessories turned off.
-4°F to 113°F (-20°C to 45°C) Six months at 100% battery charge, all accessories turned off.
113°F to 140°F (45°C to 60°C) One month at 30% - 50% charge, all accessories turned off.