Quick Start Guide
Please ensure you read the EZiSYSTEM user
manual before using this product. This Quick
Start Guide is NOT a substitute for the User
Manual.
1 Battery Level Indicator 6 Depth Display
2 LED Bar Display 7 Sonde/Line Mode
3 LED Mode Indicator 8 Display Panel
4 Function / Mode Select Key 9 On / Off Trigger
5 Depth key 10 Battery Compartment
Controls:
Switch on the EZiCAT by lifting and holding the
On/Off trigger
Switching on activates a start-up test which checks
the display LEDs, speakers and batteries.
The battery light starts to flash when approximately
20% battery life remains. Change all batteries at
the same time using quality alkaline replacements.
The EZiCAT™ always starts in POWER mode and
at maximum sensitivity for the safety of the
operator.
Pressing the Function key changes the EZiCAT™
mode between Power, Radio, 8kHz and 33kHz
Generator modes. The selected mode is indicated
by the illuminated LED.
The central LED bar indicates signal strength and
the display will rise as a service is detected, giving
a peak reading when directly over the service.
Sweep Search:
Mark out the site to be scanned.
In POWER mode cross the site from left to right,
keeping the EZiCAT™ upright. DO NOT SWING.
Mark any responses with marker paint, flags or
similar. CAUTION: Never drive pegs into the
ground over the service
Turn through 90° and repeat across the site.
Change to RADIO mode and repeat the process in
both directions.
POWER Mode RADIO Mode
Sweep Search
10
9
8
5
7
6
4
3
2
1
Question and Answer IconNeed help?

Do you have a question about the EZiCAT 200 and is the answer not in the manual?

Summary

Device Features and Controls

Device Components

Identifies key components of the EZICAT 200 including indicators, display, and controls.

Device Controls and Operation

Explains how to switch on, battery status, sensitivity settings, and mode selection for the EZICAT 200.

Sweep Search Method

Sweep Search Procedure

Details the steps for performing a sweep search in POWER and RADIO modes to locate underground services.

Advanced Detection Features

Automatic Pinpointing

Describes the EZICAT's automatic pinpointing capability for accurate service location.

Service Direction Identification

Explains how to determine the direction of a detected service using the EZICAT.

Depth Measurement

Outlines the process for measuring the depth of a service using the EZICAT with an EZITRACE generator.

Overview

The EZiCAT 200 is a sophisticated underground service locator designed for efficient and accurate detection of buried utilities. This quick start guide provides essential information for its operation, ensuring users can effectively locate and trace services while maintaining safety.

Function Description:

The EZiCAT 200 is primarily used for locating buried services such as power cables, radio signals, and signals from 8kHz and 33kHz generators. It features an intuitive display panel that includes a battery level indicator, LED bar display for signal strength, and an LED mode indicator. A depth display shows the depth of the detected service, and it supports both Sonde/Line mode. The device is equipped with a function/mode select key and a depth key for easy operation. An on/off trigger controls the device, and a battery compartment houses the power source.

Usage Features:

Controls and Operation:

To switch on the EZiCAT 200, lift and hold the On/Off trigger. Upon activation, the device performs a start-up test, checking the display LEDs, speakers, and battery status. This ensures all components are functioning correctly before use. The EZiCAT 200 always powers on in POWER mode with maximum sensitivity, a crucial safety feature for operators. The battery light will flash when approximately 20% battery life remains, signaling that new, quality alkaline batteries should be installed.

Mode Selection:

Pressing the Function key allows the user to cycle through different detection modes: Power, Radio, 8kHz, and 33kHz Generator modes. The currently selected mode is indicated by an illuminated LED, making it easy to identify the active setting.

Signal Strength and Detection:

The central LED bar serves as a visual indicator of signal strength. As the device approaches a buried service, the display will show a rising signal, reaching a peak reading when directly over the service. This peak reading helps in precisely pinpointing the location of the utility.

For a comprehensive sweep search, first mark out the site to be scanned. In POWER mode, cross the site from left to right, keeping the EZiCAT 200 upright. It is crucial not to swing the device during this process to maintain accuracy. Any detected responses should be marked with marker paint, flags, or similar indicators. A critical safety note: never drive pegs into the ground over a detected service. After the initial pass, turn 90 degrees and repeat the sweep across the site. This process should then be repeated in RADIO mode, scanning in both directions.

Automatic Pinpointing:

The EZiCAT 200 features automatic pinpointing, eliminating the need for manual adjustments. To use this feature, walk across the service from an area of 'no detection,' through the detection area, and back to 'no detection.' As you retrace your steps, the audio signal automatically adjusts, reducing the service footprint with each pass until the service is accurately pinpointed. The visual display will show a peak reading when the device is directly over the service.

Service Direction:

Once a service has been pinpointed, rotate the EZiCAT 200 until the signal display reduces to a minimum. This indicates the direction of the buried service, providing valuable information for mapping and excavation.

Depth Measurement:

The EZiCAT 200 can indicate the depth of a service when used in conjunction with the EZiTRACE Signal Generator. To measure depth, ensure both the EZiCAT 200 and EZiTRACE are set to 33kHz. Pinpoint the service and position the EZiCAT 200 at 90 degrees to its direction. Then, press the depth key to display the depth reading. It is important to note that the displayed depth refers to the centre of the buried service.

Maintenance Features:

Battery Replacement:

The EZiCAT 200 provides a clear indication when battery life is low. When the battery light starts to flash, it signifies that approximately 20% battery life remains. At this point, all batteries should be replaced simultaneously with quality alkaline replacements to ensure consistent performance and accurate readings.

Site Marking and Safety:

During sweep searches, mark out the site to be scanned and any detected responses with marker paint, flags, or similar. This practice helps in visualizing the layout of buried services. A crucial safety reminder is to never drive pegs into the ground over a detected service to prevent accidental damage or injury.

Upright Operation:

For accurate readings, especially during sweep searches in POWER mode, it is essential to keep the EZiCAT 200 upright and do not swing it. This ensures the device's sensors are correctly oriented for optimal detection.

Regular Practice:

To maintain proficiency and ensure accurate results, it is recommended to turn through 90 degrees and repeat the sweep across the site in both POWER and RADIO modes. This practice helps in confirming detections and improving user skill.

Marking Responses:

When marking responses, use marker paint, flags, or similar methods. CAUTION: Never drive pegs into the ground over the service. This is a critical safety instruction to prevent damage to buried utilities and potential hazards.

Documentation:

Always mark any responses with permanent marker paint, flags, or similar. CAUTION: Never drive pegs into the ground over the service. This practice ensures that the locations of buried services are clearly documented for future reference and to prevent accidents.

Continuous Improvement:

To enhance detection skills and ensure thorough site coverage, change to RADIO mode and repeat the process in both directions after completing the POWER mode sweep. This multi-mode approach helps in identifying a wider range of services.

EZiCAT 200 Specifications

General IconGeneral
ModelEZiCAT 200
TypeCable Locator
ManufacturerRadiodetection
DisplayLCD
Operating Frequency33 kHz
MaterialABS Plastic
Power Source6 x AA Batteries
Battery Life40 hours intermittent use