Acessory
Dip - Switch and LED signal of their functions
Connections for n°2
Junior 624 sliding
operators
It is important to determinate wich Elpro 62 MASTER will
comand and control the Elpro 62 SLAVE
All the accessories for command , signalling and safety must
be connected to the terminals of the Elpro 62 MASTER
Outputfor courtesy lamo relay max 24V 50mA
Output for
courtesy lamp
relay 24V 50mA
18 19
2
1
Pedestrian
Common
Pedestrian Input
20 23
NA input for external contact for
pedestrian opening
-
+
Pedestrian Trimmer: the opening distance
of the gate up to 3 metres is adjusted for
the Mastre Slave pedestrian opening.
Master Slave
Refer to the previous pages for the
Dip-switch composition relative to
the individual accessories and
functions.
12
ON: Elpro 62 SLAVE (2ndJunior 624)
OFF: Elpro 62 MASTER (1st Junior 624)
DIP-SWITCH 12:
n°4 x 1
carry out the following connections:
Elpro 62 MASTER Elpro 62 SLAVE
Dip-Switch 12=OFF: Dip-Switch 12=ON:
terminal 15 (open) terminal 4 (open)
terminal 16 (close) terminal 5 (close)
terminal 17-23 (common) terminal 3 (common)
terminal 22 terminal 16 (close)
terminal 17 (common) 23
terminal 1 2
terminal 3(common) 6 (stop)
!
Junior 624 - 24V dc
meccanica
FADINI
Elpro 62
GB
Photocelles opening
Input
NC
Common
2321
Input NC for photocel installed in the
opening of the gate: in case of di
obstacle is detected during the
opening, reverses the direction for
20cm about freeing the obstacle, then
blocks waiting for a command.
NC input contact 2°
Junior
2322
NC
Common
Present Jumper.
NC contact for connexion at 2° Junior
ELECTRICAL CONNECTIONS TO THE TERMINAL BOARDS AND THEIR FUNCTIONS
Electrical connections
A 4-wire cable is
necessary for the
connection between the
two Elpro 62
programmers
!
PROGRAMME JUNIOR MASTER AND SLAVE SEPARATELY ONCE THE ELECTRICAL
CONNECTIONS HAVE BEEN MADE AND THE DIP-SWITCHES SET CORRECTLY
OPEN
CLOSE
15 16 17
Master
COMMON
AP
CH
C
20 21 22 23
20 21 22 23
AP
CH
C
Slave
15 16 17
3
17
23
453 621