EasyManua.ls Logo

Fagor DDS AXD/SPD 2.75 - Page 103

Fagor DDS AXD/SPD 2.75
406 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drives
3.
Ref.1912
· 103 ·
DDS
HARDWARE
For a switching frequency fc = 8 kHz
F. H3/16
Current derating on ·AXD|MMC 1.08· drives for fc = 8 kHz.
F. H3/17
Current derating on ·AXD|MMC 1.15· drives for fc = 8 kHz.
F. H3/18
Current derating on ·AXD|MMC 1.25· drives for fc = 8 kHz.
F. H3/19
Current derating on ·AXD|MMC 1.35· drives for fc = 8 kHz.
F. H3/20
Current derating on ·AXD|MMC 2.50· drives for fc = 8 kHz.
35 40 55 60
4
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
2
6
In
0
8
Imax
AXD|MMC 1.08
T ambient In Imax.
° C ° F A A
35 95 4.0 8.0
40 104 4.0 8.0
45 113 4.0 8.0
50 122 3.5 7.0
55 131 3.0 5.9
60 140 2.4 4.8
35 40 55 60
8
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
4
12
In
16
Imax
0
AXD|MMC 1.15
T ambient In Imax.
° C ° F A A
35 95 7.5 15.0
40 104 7.5 15.0
45 113 7.5 15.0
50 122 7.1 14.3
55 131 6.7 13.4
60 140 6.3 12.5
35 40 55 60
10
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
5
15
In
20
Imax
0
25
AXD|MMC 1.25
T ambient In Imax.
° C ° F A A
35 95 12.5 25.0
40 104 12.5 25.0
45 113 12.5 25.0
50 122 11.8 23.7
55 131 11.1 22.2
60 140 10.3 20.7
35 40 55 60
20
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
25
In
30
Imax
35
15
AXD|MMC 1.35
T ambient In Imax.
° C ° F A A
35 95 17.5 35.0
40 104 17.5 35.0
45 113 17.5 35.0
50 122 16.6 33.3
55 131 15.7 31.3
60 140 14.7 29.3
AXD|MMC 2.50
T ambient In Imax.
° C ° F A A
35 95 25.0 50.0
40 104 25.0 50.0
45 113 25.0 50.0
50 122 22.2 44.4
55 131 19.3 38.6
60 140 16.3 32.7
40
I (A rm s)
Tambient
°C (°F)
(104)
In
Im ax
10
0
35
(95)
45
(113)
50
(122)
55
(131)
60
(140)
20
30
40
50

Table of Contents