EasyManua.ls Logo

Fagor DDS AXD/SPD 2.75 - Page 149

Fagor DDS AXD/SPD 2.75
406 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drives
3.
Ref.1912
· 149 ·
DDS
HARDWARE
For a switching frequency fc = 8 kHz
F. H3/100
Current derating on ·SCD 2.50· drives for fc = 4 kHz.
F. H3/101
Current derating on ·SCD 2.75· drives for fc = 4 kHz.
F. H3/102
Current derating on ·SCD 1.15· drives for fc = 8 kHz.
F. H3/103
Current derating on ·SCD 1.25· drives for fc = 8 kHz.
F. H3/104
Current derating on ·SCD 2.35· drives for fc = 8 kHz.
35 40 55 60
20
40
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
10
30
Imax
SCD 2.50
T ambient Imax.
° C ° F A
35 95 38.0
40 104 38.0
45 113 38.0
50 122 36.3
55 131 34.3
60 140 32.2
SCD 2.75
T ambient Imax.
° C ° F A
35 95 52.0
40 104 52.0
45 113 52.0
50 122 49.7
55 131 44.6
60 140 39.2
35 40 55 60
20
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
30
Imax
40
10
50
0
35 40 55 60
9
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
8
10
Imax
11
SCD 1.15
T ambient Imax.
° C ° F A
35 95 10.6
40 104 10.6
45 113 10.6
50 122 10.1
55 131 9.5
60 140 8.9
35 40 55 60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
10
Imax
11
12
13
SCD 1.25
T ambient Imax.
° C ° F A
35 95 12.5
40 104 12.5
45 113 12.5
50 122 12.2
55 131 11.4
60 140 10.7
35 40 55 60
I (Arms)
Tambient
°C (°F)
45 50
(95)
(104)
(113) (122) (131) (140)
14
Imax
16
18
20
SCD 2.35
T ambient Imax.
° C ° F A
35 95 19.5
40 104 19.5
45 113 19.5
50 122 18.5
55 131 17.2
60 140 15.8

Table of Contents