Drives
3.
180
Ref.1912
DDS
HARDWARE
· 152 ·
ACD|SCD 1.25
These drives have the following connectors:
F. H3/108
ACD|SCD 1.25 compact drives. Connectors.
1. Power connector for motor (U, V, W) and mains connection (R, S, T).
Note
. RST has been the classic nomenclature for mains phases. L1L2L3 is its equivalent
nowadays.
2. Connector for the external Ballast resistor (Re) and for accessing the power bus (L+, L-).
X1. Connector for the internal 24 V DC power supply (2-ph. with line voltage V AC).
X2. Connector for the basic control signals.
X3. Connector with two possible uses:
as output of the encoder simulator.
as input of the direct feedback for the position loop.
X4. Connector for motor feedback connection (encoder).
X5. Connector for RS-232 serial line connection.
X6. SERCOS-II or CAN interface connector.
X7. Connector for external acknowledgment of the status of the safety relay.
SL1. Slot for the cards A1, 16DI-8DO and 8DI-16DO.
SL2. Slot for the cards 16DI-8DO and 8DI-16DO.
compact drive
RESET button
top view
1
X1
X6
2
SL1
SL2
WARNING. AC touch current greater than
3.5 mA. Install a ground wire with a section
of at least 10 mm² (Cu) or 16 mm² (Al).
X7
X2
X4
X3
X5
BOOT button. Software update.