EasyManua.ls Logo

Fagor DDS AXD/SPD 2.75 - Page 215

Fagor DDS AXD/SPD 2.75
406 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Selection criteria
5.
Ref.1912
· 215 ·
DDS
HARDWARE
where:
T. H5/8 Power supply selection when using an FM7 asynchronous spindle motor with E03 release.
P
m
Maximum power that the drive may demand from the power supply in each motor-drive combi-
nation. It includes the power dissipated by the drive itself (in kW).
In star
Asynchronous
spindle
motor
Power (kW) (%)
Drive
power
Drive for
asynchronous
spindle motor
Drive
Pm
S1 S6-40 S1 S6-40
(kW)
(%)
(kW)
FM7-D055
5.5 7.7 86.0 84.5 9.1 SPD 1.35 90 10.1
FM7-D075
7.5 11.0 86.5 84.6 13.0 SPD 2.50 90 14.4
FM7-D110
11.0 15.5 90.2 89.2 17.4 SPD 2.75 90 19.3
FM7-D150
15.0 22.0 90.4 89.3 24.6 SPD 2.85 90 27.4
FM7-D185
18.5 26.0 91.8 91.5 28.4 SPD 2.85 90 31.6
FM7-D220
22.0 33.0 89.2 88.1 37.5 SPD 3.100 90 41.6
ASYNCHRONOUS FOR SPINDLE, FM7. Release E03
Maximum power consumed by the power supply (kW)
ASYNCHRONOUS
Asynchronous for spindle Pm
1
2
SUM OF POWER:
(kW)
2
Pm: Required power obtained for the asynchronous spindle drive in
S6-40% cycles. This data includes the internal losses of the drive.
In triangle
Asynchronous
spindle
motor
Power (kW) (%)
Drive
power
Drive for
asynchronous
spindle motor
Drive
Pm
S1 S6-40 S1 S6-40 (kW)
(%)
(kW)
FM7-D055
5.5 10.0 86.0 84.5 11.8 SPD 1.35 90 13.1
FM7-D075
7.5 13.0 86.5 84.6 15.4 SPD 2.50 90 17.1
FM7-D110
11.0 20.0 90.2 89.2 22.4 SPD 2.75 90 24.9
FM7-D150
15.0 26.0 90.4 89.3 29.1 SPD 2.85 90 32.4
FM7-D185
18.5 32.0 91.8 91.5 35.0 SPD 2.85 90 38.9
FM7-D220
22.0 40.0 89.2 88.1 45.4 SPD 3.100 90 50.4

Table of Contents

Related product manuals