Power supplies
2.
94
Ref.1912
DDS
HARDWARE
· 66 ·
The gap and tightening torque and sections of the screws of the plug-in
connectors for X3 and X4/X5/X6 are given by the table:
T. H2/21 Plug-in connector for X3. Technical data.
Connector data XPS-25 XPS-65
Nr of poles 3 3
Gap (mm) 7.62 7.62
Min./max. tightening torque (N·m) 0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²) 0.2/2.5 0.2/2.5
Rated current In (A) 12 12
Wire data
Length to strip (mm) 7 7
T. H2/22 3 identical plug-in connectors for X4|X5|X6. Technical data.
Data of each connector XPS-25 XPS-65
Nr of poles 3 3
Gap (mm) 5.08 5.08
Min./max. tightening torque (N·m) 0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²) 0.2/2.5 0.2/2.5
Rated current In (A) 12 12
Wire data
Length to strip (mm) 7 7
1x
3x
INFORMATION. In cases of micro-surges or total loss of mains power, this
module guarantees stable and maintained 24 V DC while the motors are
being stopped. This is an absolute must in order to comply with the EC
requirement for the machine.
i