Power supplies
2.
Ref.1912
· 83 ·
DDS
HARDWARE
Terminal strip for connecting the líne voltage input
Three-phase line input taken at a point before the three single-phase RPS
chokes (one choke per phase). This connection is needed to receive the
mains line voltages and it is done through connector (2) as shown in the next
figure:
The max. current circulating through the wires (screwed into this connector)
will be 8.5 mA for a line voltage of 460 V AC. Therefore, use wires with a
minimum section of 0.5 mm².
For further detail, see chapter 6. POWER LINE CONNECTION of this
manual.
Connection to an external Ballast resistor
RPS power supplies do not carry a Ballast circuit and, consequently,
FAGOR does not have external braking resistors (Ballast) associated with
them. In applications requiring a Ballast circuit, one off-the-shelf will have to
be installed.
F. H2/41
Connecting the line voltage input. Terminal strip.
T. H2/30 Data of the pins of the line voltage sensor connector. See
connector 2 of the previous figure.
Connector data RPS-20 RPS-45 | RPS-75 | RPS-80
Nr of poles 3 3
Gap (mm) 7.62 7.62
Min./max. tightening torque (N·m) 0.5/0.6 0.5/0.6
Screw thread M3 M3
Min./max. section (mm²) 0.2/2.5 0.2/2.5
Rated current In (A) 12 12
Wire data
Length to strip (mm) 7 7
1x
RPS-20
RPS-45/75/80
1x
L3
PE
L1 L2
U1
U2
U3
L1 L2
L3
L1
L2
L3
T1 T2 T3
LINE VOLTAGE
FEEDBACK
CONNECTOR
POWER
CONNECTOR
- KM1
CONTACTOR
CHOKE RPS
The L1-L2-L3 phases may be
connected in any sequence
from MAINS
3x0.5 mm²
cable without connectors
MPC-4x... (mm²)
1
2
MANDATORY. The phase order in the line voltage input (2) must be exactly
the same as the one selected at the power connector (1). See figure F. H6/2.