DIGITAL CONTROL, INC 60
The transmitter does not need to be paired for the locator to
read the transmitter info.
STEP 3 OF 5
Select
Transmitter
Information
.
STEP 4 OF 5
Use the
Transmitter Info
screen to check important information such as
runtime hours for warranty coverage, current band (underlined), selected
power modes, , , and max recorded
temperature.
STEP 5 OF 5
Click to return to the
Main
menu.
GLOSSARY DEFINITIONS
*TRANSMITTER OPERATING CURRENT
A reading of greater than 0.5 A or less than 0.05 A indicates electrical failure.
*TRANSMITTER BATTERY VOLTAGE
A voltage reading below 2.7 (alkaline), 3.2 (lithium) or 3.9 (LiR) indicates bad or
depleted batteries.
operating current
*
battery voltage
*