• If the burners appear to malfunction, check
the following:
– e cover of the burner is positioned
correctly.
– e ame spreader is positioned correctly.
– e burner is vertically aligned with the
nozzle of the injector.
• A complete operating test and a leak detection
must test be carried out after the installation.
• e exible pipe must be placed in such a way
that it cannot come in contact with a mobile
part of the casing and cannot pass through any
space that can become blocked.
• Traces of glue produced during manufacture in
the factory meet the standards for all hobs.
• WARNING: In the event of glass breakage
when the hob is hot: (for the heating glass/
ceramic hobs)
– Immediately stop all burners and any
electric heating element and isolate the
appliance from the power source
– Do not touch the surface of the appliance,
– Do not use the appliance.