ENGLISH
GB-36
Do not disassemble
the valve sleeve:
in the event of a
malfunction, change
the entire valve.
Before replacing
the burners on the
plate, make sure that
the injector is not
blocked.
A complete
operational must be
conducted after the
gas conversion to
detect any leakage
of gas (use soap and
water or a gas leak
detector)
After completing
the conversion,
a qualied
technician or an
installer must
mark a «V»
on the correct
category of gas to
match the setting
on the rating
plate. Remove
the previous «V»
mark.