FEASA LED ANALYSER
FUNCTIONAL VERSION
Command Summary:
s etSequenceMode# Set the No. of Fibers in the CS Mode -0 is ALL -1 is individual Channel
getsequencemode Determine which sequence mode is set
se tSequenceChannel @@ Set the Channel No's for the Capture Sequence Mode
getsequencechannel Determine which Channel No's for the Capture Sequence Mode
s etSequenceCapture### Set the Capture Time in Capture Sequence Mode (CS mode)
getsequencecapture Determine which capture time is set in CS mode
s etSequenceWait### Set the WAIT time between Captures in CS Mode
getsequencewait Determine what is the wait time between captures in CS mode
s etSequenceNumber### # Set the NUMBER of Captures to store in CS Mode
getsequencenumber Determine the number of captures stored in CS mode
s etSequenceThreshold##### Set the Intensity Threshold in CS Mode
getsequencethreshold Determine a Minimial Intensity level acceptacle as a PASS in CS mode
getSequence @ @ Get the Intensity Value in 1's or 0's based on threshold set by user
setsequencestartdelay### Set a delay time in mSec before executing a CS
getsequencestartdelay Get the delay time set before executing a CS
getsequencestored## Retrieve a previously stored CS
getSequenceTimes @@ Get the OFF.. ON.. OFF times of the Fiber in CS Mode
StoreSequence## Stores the Last CS Mode
identifysequence ## Compare the current CS Mode to Stored CS Modes
resetsequence ## Delete a CS Pattern from memory
GetMaxIntensity## Get the Maximium Intensity recorded in Sequence Capture Mode
GetMin Intensity## Get the Minimium Intensity recorded in Sequence Capture Mode
getaverageIntensity##
GetFlicker## Get the Flicker Index and Frequency after a Sequence Capture
Getfrequency## Get the Frequency and Duty Cycle of the Led under test in Sequence Capt.
EnableEOT Enable End of line transmission character
DisableEOT Disable End of line transmission character
setexternalcapture#### Set the External Trigger Capture mode
getexternalcapture Verify what capture mode the external trigger is set at.
Back to Index
124

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feasa 10-F and is the answer not in the manual?

Feasa 10-F Specifications

General IconGeneral
BrandFeasa
Model10-F
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals