MODEL S10.5DFL/850/MOT/BZ
WARNING:
This product may represent a possible shock or fire hazard if improperly installed
or attached in any way. Product should be installed in accordance with the owners
manual, current electrical codes and/or the current National Electric Code (NEC).
RISK OF ELECTRIC SHOCK: TURN OFF THE MAIN POWER AT
THE CIRCUIT BREAKER BEFORE INSTALLING.
2-Head Motion Security Flood Light
IMPORTANT SAFETY INSTRUCTIONS AND INSTALLATION GUIDE
SAVE THESE INSTRUCTIONS
READ BEFORE INSTALLATION
FEIT ELECTRIC COMPANY | PICO RIVERA, CA, USA | (800) 543-3348 | FAX (562) 908-6360 | www.feit.comFEIT ELECTRIC COMPANY | PICO RIVERA, CA, USA | (800) 543-3348 | FAX (562) 908-6360 | www.feit.com
1. J-box (not included)
2. Mounting bar
3. J-box screws (2 pieces)
4. Spacers (2 pieces)
5. Mounting gasket
6. Mounting plate
7. Terminal block
8. Mounting plate screws (2 pieces)
9. Mounting bar screw (1 piece)
10. Fixture body
11. Mounting holes
12. Decorative washers (2 pieces)
13. Decorative nuts (2 pieces)
14. Motion and photocell sensor
PARTS INCLUDED TOOLS REQUIRED
SEALANT
REV006
4. Secure Mounting
Gasket (5) and
Mounting Plate (6)
to Mounting Bar (2)
using Mounting Bar
Screw (9). Do not over-tighten.
4. Secure Mounting
Gasket (5) and
Mounting Plate (6)
to Mounting Bar (2)
using Mounting Bar
Screw (9). Do not over-tighten.
(7)
(3)
(2)(1)
Connect:
Black wire to
“L input.
Ground wire to
“GND” input.
White wire to
“N” input.
L GND
N
8. Turn power on at circuit breaker or replace the fuse.
EXTERNAL JBOX INSTALLATION
EXTERNAL JBOX
INSTALLATION
FLUSH JBOX
INSTALLATION
2. Install Mounting Bar (2)
to an External J-Box (1)
using provided J-Box
Screws (3). Add Spacer
(4) to eliminate gap
between Mounting Bar
and Mounting Plate.
1. Turn main power off at circuit breaker or fuse box.
3. Extend and feed J-Box wires through openings
on Mounting Gasket (5) and Mounting Plate (6)
as shown below.
6. Position and align the Mounting Holes (11) on
Fixture Body (10) to the Mounting Plate Screws (8).
Secure Fixture Body to Mounting Plate using
Rubber Washers (12) and Decorative Nuts (13).
7. Once fixture is tightly secured to J-Box, apply a
silicone sealant around the base of the fixture to
prevent moisture from reaching the connections.
5. Connect power supply
wires directly to
Terminal Block (7).
Secure wires to
Terminal Block by using
a small screwdriver.
See below.
See detail below
Detail
(12)(11)
(13)
(8)
(10)
(12)(11)
(13)
(8)
(10)
(6)
(5)
(6)
(7)
(5)
(3)
(2)
(1)
(4)(4)
L GND N
Connect:
Black wire to
“L input.
Ground wire to
“GND” input.
White wire to
“N” input.
L GND
N
8. Turn power on at circuit breaker or replace the fuse.
FLUSH JBOX INSTALLATION
2. Install Mounting Bar (2)
to a Flush J-Box (1)
using provided J-Box
Screws (3). Add Spacer
(4) to eliminate gap
between Mounting Bar
and Mounting Plate.
1. Turn main power off at circuit breaker or fuse box.
3. Extend and feed J-Box wires through openings
on Mounting Gasket (5) and Mounting Plate (6)
as shown below.
6. Position and align the Mounting Holes (11) on
Fixture Body (10) to the Mounting Plate Screws (8).
Secure Fixture Body to Mounting Plate using
Rubber Washers (12) and Decorative Nuts (13).
7. Once fixture is tightly secured to J-Box, apply a
silicone sealant around the base of the fixture to
prevent moisture from reaching the connections.
5. Connect power supply
wires directly to
Terminal Block (7).
Secure wires to
Terminal Block by using
a small screwdriver.
See below.
See detail below
Detail
(9)
L GND N
(6)
(5)
L GND N
(6)
(2) (2)
(4)
(4)
(5)
(9)
L GND N
(4)

(14)
(13)
(12)
(11)
(9)
(10)
(8)
(7)
(6)
(5)
(3)
(2)
THIS SIDE UP
(1)
(4)
(14)
(13)
(12)
(11)
(9)
(10)
(8)
(7)
(6)
(5)
(3)
(2)
THIS SIDE UP
(1)
(4)
Question and Answer IconNeed help?

Do you have a question about the Feit Electric S10.5DFL/850/MOT/BZ and is the answer not in the manual?

Feit Electric S10.5DFL/850/MOT/BZ Specifications

General IconGeneral
BrandFeit Electric
ModelS10.5DFL/850/MOT/BZ
CategoryFlood Light
Wattage10.5W
Lumens850
Color Temperature5000K (Daylight)
Beam Angle120 degrees
Motion SensorYes
BuzzerNo
DimmableNo
Voltage120V
Life Hours25, 000 hours
Energy Star CertifiedNo
FinishBronze
Motion Sensing Range30 feet

Summary

External J-Box Installation Steps

Power Off and Initial Mounting

Turn off main power, install mounting bar to J-box, and feed wires through gasket and plate.

Secure Mounting Components

Secure gasket and mounting plate to the mounting bar, ensuring proper alignment.

Wiring and Fixture Attachment

Connect power supply wires to the terminal block and attach the fixture body.

Final Sealing and Power Restoration

Apply sealant for moisture protection and turn power back on.

Flush J-Box Installation Steps

Power Off and Initial Mounting

Turn off main power, install mounting bar to J-box, and feed wires through gasket and plate.

Secure Mounting Components

Secure gasket and mounting plate to the mounting bar, ensuring proper alignment.

Wiring and Fixture Attachment

Connect power supply wires to the terminal block and attach the fixture body.

Final Sealing and Power Restoration

Apply sealant for moisture protection and turn power back on.

Operating Instructions and Controls

Motion Sensor Sensitivity Adjustment

Adjust the motion sensor sensitivity using the rotary control knob for optimal detection.

Timer Control Settings

Set the duration the light stays on after motion detection, from 1 to 10 minutes.

Light Operation Modes

Understand Test, Dusk to Dawn, and Timer modes for fixture operation.

Manual Override Function

Learn how to manually control the light's ON/OFF state via the wall switch.

Troubleshooting and Maintenance

Common Troubleshooting Issues

Address problems like light not coming on, coming on during the day, or cycling.

Care and Maintenance Guidelines

Instructions for cleaning the fixture and ensuring its longevity.

Safety and Electrical Precautions

Important warnings regarding electrical codes, wet locations, and dimmers.

Related product manuals