Summary

Detector Bases

Models Overview

Lists available smoke and heat detector base models and their UL compatibility.

Available Accessories

Lists accessories for detector bases, such as relays and remote indicators.

Detector Ratings

Base Electrical Ratings

Provides electrical ratings for detector bases, including standby/alarm current and voltage.

Control Unit Selection

Panel Compatibility

Refers to document 70.63 for UL compatible control panels and detector limits.

Detector Installation Guidelines

Open Area Smoke Detector Spacing

Details spacing and location guidelines for open area smoke detector installation.

Open Area Air Velocities

Lists air velocity ratings for smoke detector models in open area applications.

Open Area Mounting

Describes how detector bases are mounted on electrical junction boxes.

Open Area Heat Detector Spacing

Provides spacing and mounting guidelines for heat detectors in open area installations.

Duct Detector Installation

Duct Application General

Defines duct detection use and required accessories like Remote Test Station.

Duct Pre-installation Rules

Recommends measuring airflow and examining engineering specs for duct detection suitability.

Duct Air Velocities

Lists air velocity ratings for smoke detector models in duct applications.

Duct Installation Rules

Specifies rules for locating and installing detectors in air handling systems.

Installation and Wiring Notes

Wiring Diagrams Reference

References figures illustrating typical 2-Wire and 4-Wire detector system wiring.

Base Options and Features

Locking Feature Operation

Explains the detector base locking feature to prevent unauthorized removal.

Relay Module Installation

2 WRM Module Setup

Details the installation of a 2WRM into a 2WRLT base to function as a 2WRB.

Detector Testing Procedures

Smoke Detector Go-No Go Test

Provides step-by-step instructions for performing smoke detector go-no go tests.

Heat Detector Test Method

Details the procedure for testing heat detectors using a heat gun.

Smoke Detector Sensitivity Metering

Lists testers and reference documents for metering smoke detector sensitivity.

Detector Maintenance

Annual Cleaning

Recommends annual cleaning of detector heads using a vacuum cleaner.

Spare Parts Information

Special Considerations

Detector Disposal

Ordering Information