EasyManua.ls Logo

Fer FERtech F 24 D - User Manual

Default Icon
32 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
%
FRG%5HY
FERtech F 24 D - F 32 D
F 24 D
F 32 D
700
400
330
85
115
91
109
195
266
80
80.5
51
54
76
58.5
178
126
ABCDEF
330
Ø
110
÷
120
120
725.5
676.5
50 76 54 51 80.5 74.5
93
114
Ø
30
Ø
30
Ø
24.5
Ø
24.5
Ø
24.5
FABCD E
85
115
115
85
195
330
A
B
C
D
E
F
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
RU -
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ

Questions and Answers

  • J
    James ThompsonSep 22, 2025
    What to do if my Fer FERtech F 24 D Boiler supply voltage is under 180V?
    • A
      Alyssa MaldonadoSep 22, 2025
      If the supply voltage to your Fer Boiler is under 180V, it is due to electric mains trouble. Check the electrical system.
  • C
    Christopher LynchSep 12, 2025
    What to do if my Fer Boiler has Incorrect system water pressure?
    • A
      andrea18Sep 12, 2025
      If your Fer Boiler indicates incorrect system water pressure, it could be due to the pressure being too low. If so, fill the system. Another cause might be a water pressure switch damaged or not connected, requiring a check of the sensor.
  • M
    michael60Sep 8, 2025
    What does it mean if my Fer FERtech F 24 D Boiler has a Heating sensor fault?
    • R
      Robert JarvisSep 8, 2025
      If your Fer Boiler is showing a heating sensor fault, the sensor may be damaged. Replace the sensor.
  • J
    John CookAug 27, 2025
    What to do if my Fer Boiler has poor combustion?
    • J
      Jacob BarnesAug 27, 2025
      If your Fer Boiler is experiencing poor combustion, it might be due to an inlet/exhaust flue obstruction. To resolve this, check the flue.
  • E
    Eugene WilliamsAug 27, 2025
    What to do if my Fer FERtech F 24 D has poor combustion fault?
    • L
      lee30Aug 27, 2025
      If your Fer Boiler shows a poor combustion fault, specifically if fault F20 was generated 6 times in the last 10 minutes, refer to fault F20 for guidance.
  • J
    josephpalmerAug 29, 2025
    What to do if my Fer FERtech F 24 D shows a combustion control fault?
    • W
      wdavisAug 29, 2025
      If your Fer Boiler displays a combustion control fault, it could be related to a fan fault. In this case, check the fan and fan wiring. Alternatively, a faulty baffle or a flue that is not correctly sized or is obstructed could be the cause. Check the baffle and replace it if necessary, and check the flue.
  • A
    andreaperryAug 30, 2025
    What to do if my Fer FERtech F 24 D Boiler is showing a flame present signal with burner off?
    • M
      mullinssherriAug 30, 2025
      If your Fer Boiler shows a flame present signal even when the burner is off, it could indicate an electrode fault. In this case, check the ionisation electrode wiring. Another possibility is a card fault, which would require checking the card.
  • K
    Kimberly GrantSep 1, 2025
    What to do if my Fer FERtech F 24 D Boiler has exchanger protection trips?
    • S
      sarahhobbsSep 1, 2025
      If your Fer Boiler's exchanger protection trips, it could be due to no HO system circulation. Check the circulating pump. Another possible cause is air in the system, so vent the system.
  • J
    Jason BrownSep 13, 2025
    What does it mean if my Fer FERtech F 24 D Boiler shows a sensor positioning issue?
    • J
      jonesandrewSep 13, 2025
      If your Fer Boiler indicates a sensor positioning issue, it means that the delivery sensor or DHW sensor is detached from the pipe. Check the correct positioning and operation of the sensors.
  • D
    David FuentesSep 10, 2025
    What does it mean if my Fer FERtech F 24 D has an External probe fault?
    • C
      Carla SteeleSep 10, 2025
      An external probe fault in your Fer Boiler may be due to a damaged probe or wiring shorted. Check the wiring or replace the sensor. Another possible cause is the probe being disconnected after activating the sliding temperature, which requires reconnecting the external sensor or disabling the sliding temperature.

Summary

General Warnings

Boiler Installation

General Installation Instructions

Emphasizes installation by qualified personnel following regulations.

Installation Location Guidelines

Guidelines for selecting a suitable and safe installation location for the boiler.

Boiler Connections and Utilities

Plumbing, Gas, and Electrical Connections

Covers plumbing, gas, and electrical connection requirements and safety.

Service and Maintenance

Burner Pressure Adjustment

Steps to adjust minimum and maximum burner pressures.

Periodic Maintenance Checks

Details periodic checks for ensuring correct operation and safety devices.

Troubleshooting and Fault Diagnosis

Explains the self-diagnosis system and how to interpret fault codes.

Boiler Fault List and Solutions

A table listing fault codes, possible causes, and cures for boiler issues.