Ferroli PEGASUS 67 2S - User Manual

Ferroli PEGASUS 67 2S
64 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cod. 3540S434 — Rev. 00 - 10/2020
PEGASUS 67 ÷ 107 2S
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
KULLANMA, KURULUM VE BAKÝM TALIMATLARÝ
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
ІНСТРУКЦІЯ З ЕКСПЛУАТАЦІЇ, МОНТАЖУ ТА ОБСЛУГОВУВАННЯ
ТЕХНИЧЕСКИЙ ПАСПОРТ ИЗДЕЛИЯ
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ, МОНТАЖУ И ТЕХОБСЛУЖИВАНИЮ
IT
ES
TR
EN
FR
UA
RU

Questions and Answers

  • M
    Michael SmithAug 15, 2025
    Why are the electrodes not discharging in the ignition phase on my Ferroli PEGASUS 67 2S?
    • C
      cdavisAug 15, 2025
      If the electrodes on your Ferroli Thermostat aren't discharging during ignition, several factors could be at play. First, ensure the electrodes are correctly positioned and free of any deposits. Check that your control thermostat isn't set too low and verify the power supply. Also, inspect the connections at the ignition and ionisation electrodes, as well as the electronic flame controller. Confirm that the LINE-NEUTRAL connections aren't inverted and that the earth contacts are working efficiently. Finally, check the inlet gas pressure, look for any open pressure switches, reset the safety and fume thermostats if necessary, and ensure the room thermostat is closed.
  • E
    Eric JohnsonAug 18, 2025
    How to fix burner flames that are too high, too low, or too yellow on a Ferroli PEGASUS 67 2S Thermostat?
    • M
      Michelle TapiaAug 18, 2025
      If your Ferroli Thermostat burner isn't burning correctly, with flames that are too high, too low, or too yellow, start by checking the gas supply pressure, as a dirty gas valve filter could be the cause. Also, ensure the boiler itself is clean, as dirty gas nozzles can affect the flame quality. Finally, make sure the room where the unit is located has sufficient ventilation for proper combustion.
  • S
    Sandra StevensAug 21, 2025
    What to do if my Ferroli PEGASUS 67 2S Thermostat shuts down the boiler after several lighting attempts?
    • R
      rebekahmoralesAug 21, 2025
      If your Ferroli Thermostat is shutting down the boiler after multiple lighting attempts, try cleaning the pilot burner nozzles with compressed air. Check that there's a regular gas flow to the boiler and that all air has been removed from the pipes. Ensure the electrodes are correctly positioned and free of deposits. Also, make sure the boiler is connected to an efficient earth connection and check the connections at the ignition and ionisation electrodes.
  • I
    Ivan SteeleAug 25, 2025
    Why does my Ferroli Thermostat smell of unburnt gas and the temperature does not increase?
    • B
      Brian LopezAug 26, 2025
      If you smell unburnt gas and the temperature isn't increasing in your Ferroli Thermostat system, make sure the boiler is clean and check the flue draught. Also, check that gas consumption isn't excessive and that the 2-stage control thermostat is operating correctly. Ensure the gas valve 2nd stage operator (max. power) is fed and that gas consumption isn't less than what's expected. Verify the boiler is perfectly clean and adequate for the system, and ensure the heating pump isn't blocked.
  • A
    adrian49Aug 28, 2025
    What causes the water temperature to be too high or too low in my Ferroli Thermostat?
    • Z
      zpalmerAug 28, 2025
      If the water temperature to your Ferroli Thermostat system is too high or too low, check the correct operation of the 2-stage control thermostat. Also, make sure the heating pump is not blocked and ensure that the characteristics of the circulating pump are adequate for the system.
  • G
    Gerald WilsonSep 1, 2025
    What causes an explosion at the burner or delay on ignition in my Ferroli Thermostat?
    • L
      lopezmatthewSep 1, 2025
      If you experience an explosion at the burner or a delay on ignition with your Ferroli Thermostat, make sure the gas pressure is sufficient and that the boiler shell is not dirty.
  • H
    haileysmithSep 4, 2025
    Why is the control thermostat reactivated with too great a temperature difference in my Ferroli Thermostat?
    • J
      Jonathan BoydSep 4, 2025
      If the control thermostat in your Ferroli Thermostat is reactivated with too great a temperature difference, make sure the bulb is properly inserted in the sheath and check the operation of the 2-stage thermostat.
  • S
    Stephanie RobersonSep 7, 2025
    Why is my Ferroli PEGASUS 67 2S producing condensate?
    • A
      Andrew ShortSep 7, 2025
      If your Ferroli Thermostat is producing condensate, ensure the boiler isn't operating at too low a temperature (below 50°C). Check regular gas consumption and the efficiency of the flue.
  • K
    Kaitlyn FieldsSep 12, 2025
    Why does my Ferroli Thermostat shut down for no apparent reason?
    • J
      juliespencerSep 12, 2025
      If your Ferroli Thermostat shuts down for no apparent reason, it could be due to safety thermostat activation because of an overtemperature or fume thermostat activation.

Summary

PEGASUS 67-107 2 S Boiler Installation Guide

Introduction to PEGASUS 67-107 2 S

General description of the PEGASUS 67-107 2S boiler and its features.

PEGASUS 67-107 2 S Control Panel Overview

Details the components and access to the boiler's control panel.

PEGASUS 67-107 2 S Boiler Lighting and Shutdown Procedures

Step-by-step instructions for lighting and turning off the boiler.

PEGASUS 67-107 2 S Boiler Fault Diagnosis and Solutions

Lists common faults and their user-solvable cures for the boiler.

PEGASUS 67-107 2 S Installation Procedures

General Installation Guidelines for PEGASUS 67-107 2 S

Essential instructions for installing the boiler safely and correctly.

PEGASUS 67-107 2 S Boiler Installation Location Requirements

Specifies the necessary conditions for the boiler's installation room.

PEGASUS 67-107 2 S Plumbing and Water System Connections

Details how to connect the boiler to the plumbing and water system.

PEGASUS 67-107 2 S Gas Supply Connection Instructions

Provides instructions for connecting the boiler to the gas supply.

PEGASUS 67-107 2 S Electrical System Connection Guide

Explains how to safely connect the boiler to the electrical power supply.

PEGASUS 67-107 2 S Flue Connection Requirements

Guidelines for connecting the boiler's flue system for proper ventilation.

PEGASUS 67-107 2 S Service and Maintenance

PEGASUS 67-107 2 S Boiler Adjustments and Settings

Instructions for adjusting boiler parameters like gas pressure and temperature.

PEGASUS 67-107 2 S Boiler Commissioning Procedures

Steps for initial startup and checks by qualified personnel.

PEGASUS 67-107 2 S Boiler Routine and Seasonal Maintenance

Information on necessary maintenance tasks and safety device checks.

PEGASUS 67-107 2 S Burner Assembly Cleaning and Removal

Procedure for removing and cleaning the burner assembly and related parts.

PEGASUS 67-107 2 S Boiler Troubleshooting Guide

PEGASUS 67-107 2 S Technical Data and Characteristics

PEGASUS 67-107 2 S Dimensions and Connection Specifications

Provides physical dimensions and connection details for the boiler.

PEGASUS 67-107 2 S General View and Main Components

Identifies and describes the primary components of the boiler.

PEGASUS 67-107 2 S Technical Data Table

Presents detailed technical specifications for the boiler models.

PEGASUS 67-107 2 S Wiring Diagrams

Illustrates the electrical connections and wiring schematics for the boiler.

Ferroli PEGASUS 67 2S Specifications

General IconGeneral
BrandFerroli
ModelPEGASUS 67 2S
CategoryThermostat
LanguageEnglish