Home
Festo
Recording Equipment
CPX-CTEL-4-M12-5POL
Festo CPX-CTEL-4-M12-5POL User Manual
4
of 1
of 1 rating
59 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Description
CTE
L master module
I-Por
t
574601
1601b
[8059466]
Electrical
interface
CP
X‐CT
EL‐4‐M12‐5POL
T
erminal CP
X
2
Table of Contents
Default Chapter
3
Table of Contents
3
1 Safety and Requirements for Product Use
6
Safety
6
General Safety Information
6
Intended Use
6
Requirements for Product Use
7
Technical Requirements
7
Training of Skilled Personnel (Requirements for Staff )
7
Range of Applications and Certifications
7
2 System Overview, CTEL System
8
Overview of the CTEL System
8
Mode of Operation of the CTEL System
9
I-Port
11
I-Port Interfaces
12
Pin Allocation
12
I-Port Connecting Cables
12
Display Components
13
Overview of the LED Indicators
13
Meaning of the LED Displays
13
Address Space
15
I/O Configuration Presetting
16
DIL Switches
16
3 Installation
18
General Instructions for Installation
18
Mounting and Dismantling
19
I-Port Connecting Cables
20
Connecting the Devices
21
Connecting the Power Supply
22
Power Supply
22
Determining the Current Consumption
23
Connection with the Host System
25
Ensuring Degree of Protection IP65/67
25
4 Commissioning
26
Configuration
26
Address Assignment in the CPX System
27
Procedure for Commissioning
28
Preparing the CTEL System for Commissioning
29
Behaviour in Case of Malfunctions in Operation
30
Notes on Operation
31
Parameters
32
Overview of Module Parameters
32
Parameter "Monitoring UOUT/UVAL
33
Parameter "I-Port Configuration
33
Parameter "Behaviour after I-Port Short Circuit
35
Parameter "Device Parameter I-Port
35
Commissioning with the Operator Unit (CPX-MMI)
36
Menu Commands of the CTEL Master Module on the Operator Unit (CPX-MMI)
37
Observe Signal Statuses (Monitoring)
38
Parameterisation with the Operator Unit (CPX-MMI)
39
Commissioning with the Festo Maintenance Tool Software (CPX-FMT)
40
5 Diagnostics and Error Handling
41
Summary of Diagnostics Options
41
Diagnostic/Error Messages
42
Priorities of the Diagnostic/Error Messages
42
Diagnostic/Error Messages by CPX Error Numbers
43
Diagnostics Via Leds
44
Diagnostics Via the CPX Bus Node
45
Status Bits of the CPX Terminal
45
I/O Diagnostic Interface and Diagnostic Memory
45
Diagnostics with the Operator Unit (CPX-MMI)
46
Diagnostics with the Festo Maintenance Tool (CPX-FMT)
47
Behaviour after Lost Connection to the Device
47
Behaviour with Error at the PL/PS Supply
49
A Commissioning
50
Technical Data
50
Event Codes
53
Accessories
54
B Glossary
55
List of Abbreviations
55
Index
56
Other manuals for Festo CPX-CTEL-4-M12-5POL
Brief Description
14 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Festo CPX-CTEL-4-M12-5POL and is the answer not in the manual?
Ask a question
Festo CPX-CTEL-4-M12-5POL Specifications
General
Number of pins/wires
5
Nominal current at 40°C
4 A
Number of poles
5
Electrical connection 1, connection technology
M12x1
Degree of protection
IP65
Related product manuals
Festo CPX-CP-4-FB
136 pages
Festo CPX-AP-I-PN-M12
24 pages
Festo EtherCAT CPX-AP-A-EC-M12
44 pages
Festo VMPAL-EPL-AP
16 pages
Festo VAEM-L1-S-12-AP
18 pages